Use of proper components 

Use cable extensions and plugs that are designed for outdoor applications. Ensure that they are in good 
electrical and mechanical condition. Only cables with one conductor are to be used.   
Ensure that all materials meet the requirements of the systems`  maximum voltage, current, moisture, and 
temperature when they are exposed to sunlight. 
Under normal conditions, a photovoltaic module is likely to produce more current and/or voltage than that 
reported under Standard Test Conditions. Accordingly, the values of Isc and Voc marked on the module should 
be multiplied by a factor of 1.25 when selecting electrical components voltage ratings, conductor capacities, 
fuse type, and type of control components connected to the PV output.   
For USA:   
Refer to Section 690-8 of the U.S. National Electric Code for an additional multiplying factor of 1.25 which may 
be applicable.

   

The maximum series fuse rating is 15A for both 60 & 72 series modules. 

The maximum reverse current is known as series fuse rating multiplied by a factor of 1.35. Each module (or 
series string of modules so connected) shall be provided with the maximum series fuse as specified. 

 

Bypass Diodes 

When modules in series are partially shaded, it may cause reverse voltage across cells or modules, this may 
cause undesirable heating to occur. The use of a diode to bypass the shaded area can minimize both heating 
and array current reduction.   
All Hanwha SolarOne modules are equipped with factory installed bypass diodes. The factory installed diodes 
provide proper circuit protection for the system. 

 

Others 

During installation, be sure to tie the cable from the junction box to the mounting substructure with nylon line, 
etc. to avoid direct contact of the cable with the back surface of the module. 

 

LIMITED ENVIRONMENTAL CONDITIONS 

Hanwha SolarOne`s Limited Warranty for module is based upon modules being mounted in accordance with 
following conditions

 

 

Operating conditions 

The operating temperature of Hanwha SolarOne module should be within -40°C to 85°C (-40°F to 185°F).   
Ensure adequate ventilation behind the module, especially in hot environments. 
Modules should be installed at least 500m from the sea to avoid corrosion due to exposure to salt. Other 
sources of corrosion, including Sulfur (Sulfur sources such as volcanoes), can also lead to performance 
degradation and should be avoided.   

 

Location conditions 

The following locations should be avoided when installing a module: 

1.

 

Location with potential for extreme sand and dust damage 

2.

 

Location with extreme air pollution, chemical vapors, acid rain, and/or soot, etc. 

3.

 

Location with extreme hail and/or snow 

4.

 

Location with potential extreme salt damage 
 

MAINTENANCE AND CARE 

Dirt on the surface of solar module may  decrease the power generation. Hanwha SolarOne  modules  have a 
self-cleaning  function  under  rainfall  weather  condition.  Module with a mounted tilt angle more than 15

°

is 

more effective than other mounting angle. If heavy soiling build-up is excessive on module glass, use a soft cloth 
and water for cleaning. CAUTION: DON`T USE ABRASIVE DETERGENTS. Please consult with system designer to 
decide the cleaning frequency according to local environmental conditions. Once a year, check the electrical and 
mechanical devices to ensure every connection is tight. The system must be periodically inspected. 

 

Содержание HSL60P-PA-0-235K

Страница 1: ...V module 60 series HSL60P PA 0 235K HSL60P PA 0 240K HSL60P PA 0 245K 72 series HSL72P PA 0 280K HSL72P PA 0 285K HSL72P PA 0 290K HSL72P PA 0 295K Hanwha SolarOne Qidong Co Ltd 888 Linyang Road Qidon...

Страница 2: ...lting from improper installation handling or misuse Ensure that the module is used only in applications for which it is suitable see Installing Module All work on a PV system installation setup mainte...

Страница 3: ...ive maximum sunlight throughout the year Specially in the Northern Hemisphere the modules should face South And in the Southern Hemisphere the modules should face North Do not fit solar modules and wi...

Страница 4: ...d professional engineer and in compliance with local codes The applied torque is same that of standard mounting OTHER Other method s certified by a registered professional engineer and in compliance w...

Страница 5: ...ng Part list Clamp type clamp M6 Bolt Note The Mounting Bolt and Nut must tighten the exact location Mounting Hole Otherwise The Mounted Module could break during operation Hole Position Dimension 60s...

Страница 6: ...one of the following grounding methods The Grounding method 1 Standard Grounding GND HOLE POSITION MODULE CENTER GROUNDING SYSTEM 4 HOLE Grounding Hole 4 Bolt M4XL25 Nut M4 Washer M4 type Torque 3 5...

Страница 7: ...it protection for the system Others During installation be sure to tie the cable from the junction box to the mounting substructure with nylon line etc to avoid direct contact of the cable with the ba...

Отзывы: