Sep 1, 2014
Version: HW3.819.
242
SCV1 Page
6
/
11
Secure the module along the long edges with the correct number of clamps. Use all the mounting points provided
and avoid direct contact between glass and metal (e.g. mounting rails).
2-3.
Module Specification
HSL72 Series HSL60 Series
2-4.
Mounting Methods For Hanwha SolarOne Modules
Option A: Clamping mounting
The module may be clamped only in the permitted
clamping areas as indicated on following drawings.
And the module clamps must not overlap the glass or
shade the module surface.
Recommended tightening torque: 5Nm.
Option B: Bolting mounting
Use the existing installation holes instead of drilling
additional holes for installation (Drilling holes shall
against the reliability and warranty of the module).
The installation and attachment materials (nuts,
bolts, etc.) must be corrosion-resistant.
Recommended tightening torque: 5Nm.
Option A: Clamping drawing