background image

  

 

 

Doc No. IM4772-7 

Page 5 of 14 

 

 

iSense

  

 

Inventory 

Your iSense box should contain the following as standard: 

 

1x iSense unit 

 

1x Knuckle joint antenna (G205) 

 

1x Battery Pack* (G213) 

* If you have ordered an externally power unit then you will also either have a desktop power supply or 24V 
DC truck power adaptor pre-fitted, instead of a battery

 

WARNINGS  

A battery pack must NOT be fitted when the external supply is used.  

The desktop power supply is not rated for outdoor use, if you wish to use this outdoors then enclose 
the whole in a suitable plastic or fibre glass enclosure 

Use only the supplied mains adaptor with these devices. 

 

Содержание IM4772 iSense

Страница 1: ...IM4772 iSense Instruction Manual...

Страница 2: ...4 Vehicle Mounting 6 3 5 Adding iSense to Synergy 7 3 6 Sensor operation 7 3 7 Alarm Handling 7 4 Setting Up the iSense Hardware 8 4 1 Removing the Front Panel 8 4 2 Connecting the Aerial 8 4 3 Connec...

Страница 3: ...10 Adds information on redirector service and USB configuration utility MSH 3 28 September 2011 Add 3 channel thermistor connections MSH 4 8 October 2014 Update for Synergy Radiolog GPRS no longer sup...

Страница 4: ...ynergy collects data associated with your iSense sensor s by making an outgoing TCP IP connection to the IMC Remote Data Service As this connection is made to a standard HTTP port on the IMC Remote Da...

Страница 5: ...unit then you will also either have a desktop power supply or 24V DC truck power adaptor pre fitted instead of a battery WARNINGS A battery pack must NOT be fitted when the external supply is used Th...

Страница 6: ...mounting box 3 4 Vehicle Mounting IMC strongly recommend that the iSense is mounted inside the vehicle body in any case the iSense unit needs to be protected from extremes of temperature changes and w...

Страница 7: ...be re triggered until three logs have been within the alarm limits The device sends its battery voltage with each message this can be viewed via Synergy 3 7 Alarm Handling It is possible to set level...

Страница 8: ...panel has been removed the battery pack will be visible on its reverse side This now leaves the back panel open and the iSense circuit board accessible 4 2 Connecting the Aerial There are two types o...

Страница 9: ...screw and remove the lid connect the vehicle supply cable as below Yellow Red wires iSense ve connect to terminal 8 Blue Green wires iSense ve connect to terminal 7 Black Blue wires Vehicle ve connect...

Страница 10: ...Pin Lemo socket JP5 Both of these areas of the iSense are shown in Figure 3 below Input Type JP1 Pin Connection Channel Type 1 channel pulse counter Pin 1 2 channel 1 2 channel pulse counter Pin 1 2 c...

Страница 11: ...s Figure 5 Opening Terminals 3 and 4 To attach the probe to the circuit board loosen the input glands Figure 4 above thread the exposed wires up the gland until there is enough length for the wire to...

Страница 12: ...her DC only clamps are connected in a similar manner Channel No ve ve 1 Green pin1 Black pin2 2 Red pin3 White pin4 3 Yellow pin5 Blue pin6 Any unused pairs should be twisted together J091 OUTPUT www...

Страница 13: ...the V093 coloured wires into the correct output terminal situated on each of the clamps to be used 4 The bottom of the clamp indicates which side of the terminal is positive negative Use this in conju...

Страница 14: ...Doc No IM4772 7 Page 14 of 14 iSense Figure 8 Connecting a JO91 3...

Отзывы: