Circuit fault

 

Contact the distributor

 

The alarm give alarm 

after the warm up 

Too  much  smoke,  alcohol  or 
perfume  or  other  volatility  gas  in 
the air. 

Move the clean air 

and test again 

Stored too long

 

Warm up for more than 

2 hours

 

Circuit fault

 

Contact the distributor 

or factory maintain

 

 

7. Notices: 

7.1 

It’s possible that the detectors give alarming in the conditions of long time smoking, 

drinking, or using perfume, gasoline, paint and other volatile organic compound

 

7.2 Please do not use or store the detectors in the corrosive gases(such as Cl

2

); 

7.3  please  do  not  use  some  non  calibrated  gas  to  test  the  detectors,  If  the  gas 
concentration is too high, it will damage the detectors, also is harmful for human’s health; 
7.4 Clean the dust or dirt on the alarm frequently to keep air vent freely and the lights clear 

7.5 The detector needs to be keeping power on for more than 24 hours after a long time 

delivery of storage. 

8 Gas Safety Knowledge: 

8.1 

Sorts of gases 

Normal domestic gas

LPG: propane and butane

   

Coal Gas

hydrogen and carbon monoxide

 

Natural Gas

methane

 

All of the normal domestic gases is combustible gas, whose LEL (lowest explode limited) is 

below 10% of mixture with air. 
When  the  concentration  of the  leaking  gas  in  air,  it  will  narcotize people’s  centre  nerve, 

even cause suffocation. 

 

8.2 

When the gas burning, it need abundant air, such as 1m

need about 30m

.So the 

placed with hearth such as kitchen has to be keep ventilate. 

8.3 

LEL Meaning: 

LEL is Lowest Explode Level. That is the lowest concentration of the gas in the air, 

which will cause exploding when meeting fire.   

8.4 

Reasons of gas leakage: 

  Wrong ignition. 

  The fire is put out with winds during the cooking. 

Gas 

Basis 

Exploding Range 

Toxicity 

LPG 

C

4

H

10

C

3

H

8

 

1.8%

9.5% 

suffocation 

Natural Gas 

CH

4

 

5%

15% 

suffocation 

Coal Gas 

H

2

CO 

4%

75% 

toxicosis 

Содержание GD Series

Страница 1: ...GD Series Gas Alarm Operation Manual Hanwei Electronics Co Ltd...

Страница 2: ...factured with advanced technology It provides visual and audible signals when the gas concentration reaches the presetting range and reminds you to take prompt favorable action 2 Specifications Model...

Страница 3: ...ded Near the windows or passage with strong wind Water fog and drop or such moist place Easy polluted or high tem environment near Oven Covered by other things 4 3 Choosing a proper installation way p...

Страница 4: ...9070 80 3 Installation 2 Choose a suitable wall or place per the above 4 1 4 2 requests Fix a nail size 2 into the wall Hang the appliance on the nail with the hanging hole as the drawing below 4 4 Co...

Страница 5: ...he alarm with function of gas shut off valve shall output one close pulse signal each 10 seconds 5 1 3 Once the gas concentration around drop under the preset alarming level the detector will stop ala...

Страница 6: ...alarm frequently to keep air vent freely and the lights clear 7 5 The detector needs to be keeping power on for more than 24 hours after a long time delivery of storage 8 Gas Safety Knowledge 8 1 Sort...

Страница 7: ...Other reasons 8 5 Solutions of gas leakage Put out the fire Shut off the gas valve Open the windows and doors Check the leakage source Don t try to turn off any electric equipment when alarming contin...

Страница 8: ...HANWEI ELECTRONICS CO LTD No 169 Xue Song Road National Hi Tech Zone Zhengzhou 450001 Henan China Phone 86 371 67169070 67169080 Fax 86 371 67169090 E mail sales hwsensor com Website www hwsensor com...

Отзывы: