suitable  power  source.  The  device  will  be  power  on  automatically 
and a battery symbol is displayed on the screen. The symbol shows 
the charging status. When the symbol is all balck and no changes, 
the charging is finished. When charged enough, the battery symbol 
is full of black color. Then please disconnect the charger from both 
the device and power source.   
 
 
 
 
 
 
 
 

7.  USB communications (optional function)                                                                 

This function is only available for the device which includes CD and 
USB data cable.   
 
Connect  the  USB  data  calbe  correctly  between  the  device  and 
computor.  Then,  run  the  matching  program  as  insturcted  in  the 
manual for the software.   
 
For details, please refer to the software manual.   
 

8.  Using and replacement of sensor modules                                                         

The device adpots smart sensor modules, which are suggested be 
calibrated every 6 months If life span is overdue, please contact the 
seller for replacement.   
 

9.  Standard accessories                                                                                               

Hand ring 

1 pc   

Alligator clip 

1 pc 

Calibration cover  1 pc 

Operation manual 

1 copy 

Charger 

1 pc 

 

 

WARNING! 

 

It

’s forbidden to charge the device in working area.   

 

During charging, the detector has no detection function.   

 

Avoid charging when device is power on. Otherwise, the 

charging speed will be influenced.   

Содержание E6000

Страница 1: ...E6000 Portable Multi Gas Detector Operation Manual Ver HW1403180296 Read this manual carefully before using this device...

Страница 2: ...5 8 of this manual Periodic Bump test will test the response feature of the sensor Please make sure that the visual audible and vibrative alarm signals are ok Only accessories which are specified for...

Страница 3: ...ry should be discarded by qualified withdrawers It s forbidden to disassembly adjust or repair the device without permission Please avoid the device falling from high place or serious shocking Any oth...

Страница 4: ...s Design of self test self diagnose and self repairing Password management Intrinsically safe design 3 Technical specification Detecting method Natural diffusion Target gas Refer to the Annex 1 in the...

Страница 5: ...lti Gas Detector Henan Hanwei Electronics Co Ltd 4 Explosion proof grade Exia IIC T4 Ga Ingress protection IP66 Dimensions and weight 168mm 91mm 45mm about 500g 4 Structure and functions Appearance Di...

Страница 6: ...or more than 3s and the device will be power on The screen shows as below After power on the detector will proceed self test and display is as below drawing The device will make self test on the buzze...

Страница 7: ...rmittent beep twice Then machine is power off 5 3 Bump test Every day before using the device the user is suggested carry out Bump test so as to check if the device is working normally Test method Whe...

Страница 8: ...e enters into common menu setting interface Below is the button function Menu Submenu Remarks DATE TIME When changing the date or time the selected bit will blink ALARM MODE When changing the mode the...

Страница 9: ...er can also exit without saving changes by pressing 5 4 2 Advanced menu In the interface of common menu interface press both and simultaneously twice The screen shows password inputting interface Inpu...

Страница 10: ...bmenu Remarks SAFETY DEPLOY To set user s ID ZERO CAL Zero calibration DATA UPLOAD Data upload PERIPHE CONFIG One mode must be selected POWER MANAGE Activate the other function LANGUAGE SELECT One mod...

Страница 11: ...zero drift of the gas sensors If finding the reading in clean air is not zero please make zero calibration by following Clause 6 7 and 6 8 of this manual 5 6 Status review In normal detection mode pre...

Страница 12: ...5 8 1 Enter the setting interface While the device is power off hold both and buttons simutaneously for about 3 seconds Then the device first performs a self test as after power on and after a short...

Страница 13: ...rns black Then press to enter the submenu 5 8 2 Zero calibration Select icon and press to enter auto zero calibration interface shown as below When finished a icon displays for gas succeed and for gas...

Страница 14: ...alibration manually After that a icon displays for gas succeed and for gas failed shown as below 5 8 3 Span Calibration After zero calibration the device displays a countdown interface shown as below...

Страница 15: ...d press to change the figure After changing the figure press button to save and enter the gas inputting mode shown as below When the device senses the input gas it displays as below During this period...

Страница 16: ...manual calibration Once finishing calibration one sensor the device starts to calibrate the next sensor one by one The operation is same as above During calibration period press and the user can skip...

Страница 17: ...move the cursor After adjusting press button to save Then the device enters setting interface of the next alarm point Note H High alarm point L Low alarm point ST STEL alert point TW TWA alert point 5...

Страница 18: ...11 Password setting Move the cursor to the incon and press button to enter the submenu shown as below Press to adjust the figure and press button to move the cursor After setting press to save the ne...

Страница 19: ...and USB data cable Connect the USB data calbe correctly between the device and computor Then run the matching program as insturcted in the manual for the software For details please refer to the softw...

Страница 20: ...it immediately System breakdown Contact the seller Circuit fault Contact the seller No response to gas Warm up not finished Wait till it finishes Circuit fault Contact the seller Reading of gas level...

Страница 21: ...se the device to other harsh environments including excessive cold heat humidity electromagnetc field and intense light Clean the housing of the device by using damp cloth Do not use corrosive agents...

Страница 22: ...LEL 50 LEL N A N A H2 0 100 LEL 20 LEL 50 LEL N A N A H2 0 1000ppm 35ppm 250ppm N A N A O2 0 30 vol 19 5 vol 23 5 vol N A N A H2S 0 100ppm 10ppm 15ppm 10 15 CO 0 1000ppm 35ppm 200ppm 35 200 CO 0 2000...

Страница 23: ...E6000 Portable Multi Gas Detector Henan Hanwei Electronics Co Ltd 22...

Страница 24: ...HENAN HANWEI ELECTRONICS CO LTD No 169 Xuesong Road National Hi Tech Zone Zhengzhou 450001 Henan China Phone 86 371 67169070 67169080 E mail sales hwsensor com Website www hwsensor com...

Отзывы: