8.3
Serial Function operating method
1. Turn on the power by pressing the POWER switch.
2. Push the SERIAL button down to light up the indicator, the dual
power supply is now working under serial condition, the maximum
voltage output is from 0~60V.
3. When adjusting both the voltage setting knobs independently, the
total output voltage is the sum of 2 voltage readings from the LCD
display.
4. Push the SERIAL button down again, the indicator will be off, and
this dual power supply will work independently.
Notice
: When operating at constant current condition, the constant
current value should be set at the same value.
Fig 5
18