uses as a trigger.
Set Trigger System
Set Edge Trigger
The trigger determines when the oscilloscope starts to acquire data and display a wave-
form. When a trigger is set up properly, it can convert unstable displays or blank screens
into meaningful waveforms.
If the oscilloscope wants to acquire a waveform, it collects enough data so that it can
draw the waveform to the left of the trigger point. The oscilloscope continues to acquire
data while waiting for the trigger condition to occur. The oscilloscope continues to ac-
quire enough data so that it can draw the waveform to the right of the trigger point after it
detects a trigger.
The
Edge
trigger determines whether the oscilloscope finds the trigger point on the ris-
ing or the falling edge of a signal. Select
Edge
trigger mode to trigger on
Rising
edge or
Falling
edge.
Mode
: Select the trigger mode.
Sweep
: Set the sweep mode to
Auto
,
Normal
or
Single
.
Auto
: Acquire waveform even no trigger occurred
.
Normal
: Acquire waveform when trigger occurred.
Single
: Acquire waveform when trigger occurred then stop
.
Source
: You can use the trigger source options to select the signal that the oscilloscope
48
Hantek1008
Содержание 1008
Страница 1: ...Hantek 1008 DIGITAL OSCILLOSCOPE USER SMANUAL Hantek1008...
Страница 2: ...Hantek1008 0 0 Version 1 Hantek 1008 X DIGITAL OSCILLOSCOPE USER S MANUAL...
Страница 8: ...4 Choose a destination directory Click Next to continue Hantek 1008 DIGITAL OSCILLOSCOPE...
Страница 9: ..._ 5 Check the setup information Click Next to start copying les Hantek1008...
Страница 11: ...XW 8 The installation is completed Hantek1008...
Страница 13: ...XY 4 New hardware search wizard starts Hantek1008...
Страница 14: ...XZ 5 Select the speci c location Hantek 1008 DIGITAL OSCILLOSCOPE...
Страница 15: ...X 6 New hardware search wizard starts to search the driver Hantek1008...
Страница 19: ...X_ Correct Compensated Over compensated Hantek1008...
Страница 27: ...Y The Menu System The Main Menu 1 File load or save data setup 2 View Change the user interface Hantek1008...
Страница 29: ...Y_ 8 Utility Utility setting 9 Window Window setting 7 Acquire Run stop or other operation setting Hantek1008...
Страница 30: ...Y 11 Help Turn on help le 10 Vehicle Vehicle setting Hantek 1008 DIGITAL OSCILLOSCOPE...
Страница 42: ...X The following picture shows the waveform of inversion Hantek 1008 DIGITAL OSCILLOSCOPE...
Страница 66: ...The grid shows 65 Hantek 1008 DIGITAL OSCILLOSCOPE...
Страница 67: ...Intensity Click Display Intensity in main menu The grid not shows 66 Hantek1008...
Страница 71: ...The Print report 70 Hantek1008...
Страница 76: ...Signal in X Y Format 75 Hantek 1008 DIGITAL OSCILLOSCOPE...
Страница 82: ...Chapter 5 Appendix Appendix A Speci cations Appendix B General Maintenance 81 Hantek 1008 DIGITAL OSCILLOSCOPE...