![Hansol Hurricane-AW Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/hansol/hurricane-aw/hurricane-aw_manual_3682049009.webp)
Hurricane-AW
8
4.4. channel 1: Angle (Starting address)
Ignition and flame jet box is located at 90 degree position originally. When it receives dmx signal, it moves to
0 degree position. This Channel is for setting shooting angle and each angle is determined by dmx key value.
4.5. Channel 2: Flame – solenoid valve (Starting a1)
This flame channel is for making your own sequences or manual flame shooting. Under the condition of pump
and electric spark working, the flame channel works. Under that condition, when you turn on this channel, you
can shoot a single flame as you wish in shooting time and shooting angle. If you do not want to use pre-
programmed sequences, you can make your own sequences with this flame channel.
This channel is locked for 10 seconds for safety reason whenever the device is power on.
4.5. Channel 3: Electric Spark (Starting a2)
The third channel (starting a2) activates the electric spark with dmx values 200 and 255. Only after
pump starts, it can work. Without pump start, this electric spark channel does not work.
4.6. Channel 4: Pump (Starting a3)
Hurricane AW has 2 pumps inside the device. After pump pressurizes fuel upto 18bar, it goes into the standby
mode(stop working) and when the pressure falls below 14 bar, it works again to get 18 bar.
4.7. Channel 5(Starting a 4): Program of Stepp Sequence of single flame shot
Hurricane AW has a number of pre-made sequences, allowing you to access certain sequences with 5
th
channel
Below, you can find a single flame shot(20ms, 0.2sec.) at each angle of dmx key value.
Chart 1 : CH5 single stepp sequence with dmx key value
(O means shooting flame for 20ms)
CH
DMX key
0
°
22.5
°
45
°
67.5
°
90
°
112.5
°
135
°
157.5
°
180
°
CH 5
0-75
x
x
x
x
x
x
x
x
x
76-95
O
96-115
O
116-135
O
136-155
O
156-175
O
176-195
O
196-215
O
216-235
O
236-255
O