8 - 17
Hanskamp AgroTech B.V. (the Netherlands)
www.hanskamp.nl/en
Black V anti-mors
EN
Black V anti-spill/anti-verschütt/anti-gaspillage
Sticker maintenance:
Keep the safetystickers clean and clearly visible. Clean the stickers with soap and water.
Do not use dissolving or corrosive solutions that can damage the stickers. Replace mis-
sing or unreadible stickers. Safety stickers are available at Hanskamp. Please refer to
the article numbers when corresponding.
Installation:
Before installing anything, check if all parts are available using the parts list at the back
of this manual. For this, refer to Annex 5 and 6 (if applicable).
1.
Determine where the Black V should be installed, and at what height. It is re-
commended to mount the Black V inside, or proximate to the feeding station.
Dimensions of the Black V are shown in Annex 1. Mounting examples are can be
found at www.hanskamp.nl/en.
2.
Connect the Black V to a storage tube with an inside diameter of 110mm (fig. 5).
3.
Make sure the power to the control unit is shut down. For this, please refer to
the corresponding manual.
4.
Use a six-core cable the connect the Black V to the control unit. Mount the cable
to the RIM motor first, according to the wiring scheme (Annex 2). Next, connect
the other end of the cable to the control unit’s output. This can be the next avai-
lable feeding slot on the feed station. The motor’s standard rotating direction is
counterclockwise. For connecting the Black V to DeLaval Feed 2/Alpro/Delpro
feed stations, a wiring scheme is shown in annex 3. For connecting to other con-
trol units, please refer to the corresponding manual.
Important!
Make sure the wiring is properly secured out of the reach of the animals. This
can result to dangerous situations.
Danger! The Black V is now under electrical voltage!
5.
The Black V is actuated completely electrical. Please pay attention to the maxi-
mum allowable amperage, which is indicated on the power source. Further-
more, ensure that the pressure on feeder auger exerted by the feed does not
exceed 50kg.
Important!
When installing the Black V, please ensure that the pressure on feeder auger
exerted by the feed does not exceed 50kg.
6.
The dosing disc should be mounted on the auger in the correct orientation, at
which the fall-out hole of the disc is facing upwards. After dispensing a portion
of feed, this disc should have the same orientation. This makes sure the concen-
trate is not spilled out of the feeder. To ensure this, follow the steps below.
Keep a test-tag in front of the tag-reader. The auger will rotate for a mo-
ment.
When the auger has stopped rotating, shut down the power of the out-of-
parlour feeder, to prevent the auger from turning unexpectedly.
Loosen the bolt that is holding the dosing disc in place, and consequently
rotate the dosing disc in the correct horizontal position (fig. 6).
Fasten the bolt again, so that the disc is firmly secured to the auger.
Turn on the power supply of the out-of-parlour feeder.
Storage tube
Orientation dosing disc
6
Storage tube for Black V
5