Hansen HGV1 Скачать руководство пользователя страница 2

2

G409d 
JAN 2013

Hansen Technologies Corporation
400 Quadrangle Drive, Suite F
Bolingbrook, Illinois 60440 USA
Tel: 630.325.1565  Fax: 630.325.1572  Toll: 866.4HANSEN  
Email: [email protected]  Web: www.hantech.com

USA  ∙  Asia   ∙  Europe  ∙  India  ∙  Latin  America  ∙  Middle East

© 2013 Hansen Technologies Corporation

INSTALLATION DIMENSIONS (inches)

SERVICE AND MAINTENANCE

Hansen gauge valves require practically no service 
or maintenance due to the combination of polished 
stainless steel stem and reliable O-ring stem seal plus 
graphite composite packing. However, if tightening 
is ever needed, use a 3/8" open end wrench or an 8" 
adjustable wrench. Extrusion of some black graphite 
packing material along the stem is normal.

If the O-ring or the adjustable packing ever needs 
replacement as evidenced by refrigerant or oil leakage at 
the stem, isolate valve from the system and evacuate to 
zero pressure in accordance with appropriate practices.

Seal caps [1/4" (P/N 50–1071), 3/8"–1/2" (P/N 50–1036)] 
or bar handles [1/4" (P/N 50–1069), 3/8" (P/N 50–1075)] 
can be easily retro-fitted to valves in the field. All 
bodies have seal cap threads; simply screw seal cap 
with O-ring onto these threads. Bar handle kit comes 
with pin partially installed in handle Place handle on 
stem and turn clockwise to close valve. Begin to push 
pin through handle and valve stem using pliers, then 
tap with hammer to finish.

CAUTION

Hansen valves are for refrigeration systems only. Read 
these instructions completely before selecting, using, 
or servicing these valves. Only knowledgeable, trained 
refrigeration technicians should install, operate, or 
service these valves. Stated temperature and pressure 
limits should not be exceeded. Bonnets should not 
be removed from valves unless the system has been 
evacuated to zero pressure. See also Safety Precautions 
in the current List Price Schedule and the Safety 
Precautions Sheet supplied with the product.

WARRANTY

Hansen valves are guaranteed against defective materials 
or workmanship for one year F.O.B. our factory. No 
consequential damages or field labor is included.

FPT X FPT, ANGLE

FPT X FPT, GLOBE

1/4" Transducer Valve

MPT X FPT, ANGLE

MPT x FPT, LONG NECK

ORDERING INFORMATION

SIZE

(mm)

A

A'

B

C

E

F

G

H

H'

J

1/4"

(7)

2.09

(53)

2.57

(65)

1.11*

(28)

1.26

(32)

1.00

(25)

0.59

(15)

2.28

(58)

2.22

(56)

2.71

(69)

0.47

(12)

3/8"

(10)

2.94

(75)

3.57

(91)

1.44

(37)

1.88

(48)

1.63

(41)

0.72

(18)

3.22

(82)

3.07

(78)

3.70

(94)

0.59

(15)

1/2

"

(13)

2.94

(75)

3.57

(91)

1.44

(37)

1.88

(48)

1.63

(41)

0.72

(18)

* THE B DIMENSION FOR HGV1, HGV1H, & HGV2 IS 3.25" (83MM)

DESCRIPTION

SEAL 

CAP

BAR 

HANDLE

BARE 

STEM

1/4" MPT x FPT, Angle, Long Neck

HGV1*

HGV1H

HGV2

1/4" MPT x FPT, Angle

H7771*

H7771H

H965

1/4" FPT x FPT, Angle

H7772

H7772H

H967

1/4" FPT x FPT, Globe

H957C

H957H

H957

1/4" MPT x FPT x FPT, Transducer Valve

H9490

3/8" MPT x FPT, Angle

H7773

H7773H

3/8" FPT x FPT, Angle

H7774

H7774H

3/8" FPT x FPT, Globe

H958C

H958H

1/2" MPT x 3/8" FPT, Angle

H7777

1/2" MPT x 1/4" FPT Angle

H7778

†  

LONG NECK VALVES PROVIDE ADDITIONAL LENGTH FOR INSULATION AND 
PRESSURE GAUGE TURNING CLEARANCE.

*  HGV1 AND H7771, AVAILABLE AS WELDED INLET VERSIONS, HGV1W AND 

H7771W PAINTED BODY.

TO ORDER:

  Specify Catalog Number.

TRANSDUCER VALVE

The H9490 Transducer Valve can be installed wherever 

pressure monitoring is desired. Turn stem all the way 
in (clockwise) and seat to isolate pressure from both 
gauge and transducer ports. Turn stem all the way out 
(counter-clockwise) and seat to isolate pressure from 
the gauge port. With stem in middle position, both 
ports are active.