OPERATION

HCK4 check valves are normally closed valves.  As 
inlet  pressure  increases,  it  overcomes  the  closing 
spring force.  As the seat disc is pushed back and away 
from the seat cartridge, flow through the valve occurs.  

The  valve  will  remain  open  until  the  inlet  pressure 

drops below the closing spring force or there is a flow 
reversal, at which time the seat disc will close against 
the seat cartridge, preventing reverse flow.

SIZING

Check valves are normally selected on the basis of line 
size.  However, for gas flow applications at low load 
conditions, a minimum of 1 psid across the valve is 
essential.  This will maintain valve at full open position.  
Valve  Cv  (Kv)  is  listed  in  the  installation  dimension 

table on page 2.  Factory valve sizing assistance is  
available.

SERVICE AND MAINTENANCE

These  valves  are  a  reliable  part  of  a  refrigeration 

system.    However,  if  valve  does  not  appear  to  be 
operating satisfactorily, isolate it from the refrigeration 
system.  Remove all refrigerant from associated piping 
and valves.  Follow the guidelines in the caution section.  
Loosen  each  flange  nut  on  the  check  valve.    Break 
each flange gasket seal.  Carefully loosen flange bolts 
one at a time, being cautious to avoid any refrigerant 
which still may be present.  Remove check valve from 
flanges and inspect.  Lapped seating surfaces should 

be smooth and free of pits or scratches.

To confirm valve operation, move seat disc with eraser 

end of pencil.  Movement should be free from friction.  
If  not,  disassemble  and  visually  inspect  for  dirt  in 
valve or burrs on seat disc.  Clean or replace parts 
as necessary.  Valve discs and seats can be restored 

by lapping on a flat plate.

Reassemble valve and insert between flanges.  Replace 
and  tighten  bolts  and  nuts  evenly.    Carefully  check 
for leaks before returning to service.

CAUTION

Hansen check valves are only for refrigeration systems.  

These instructions and related safety precautions must 

be completely read and understood before selecting, 
using, or servicing these valves.  Only knowledgeable, 
trained refrigeration mechanics should install, operate, 

or  service  these  valves.    Stated  temperature  and 
pressure limits should not be exceeded.  Valves should 
not be removed unless system has been evacuated 
to  zero  pressure.    See  also  Safety  Precautions  in 
current  List  Price  Bulletin  and  Safety  Precautions 
Sheet  supplied  with  product.    Escaping  refrigerant 
might cause personal injury, particularly to the eyes 
and lungs.

WARRANTY

A ll  Hansen  products,  except  electronics,  are 

guaranteed against defective materials or workmanship 
for one year F.O.B. factory. Electronics are guaranteed 
against  defective  materials  or  workmanship  for  90 
days  F.O.B.  factory.  No  consequential  damages  or 
field labor is included.

ORDERING INFORMATION

TYPE

PORT SIZE 

INCHES (mm)

FLANGE CONNECTION 

STYLE & SIZES

FPT, SW, WN

ODS

STD

ALSO

STD

HCK4-2

5/8” (16)

1/2”

3/8”, 3/4”

5/8”

HCK4-3

3/4” (20)

3/4”

1”, 1-1/4”

7/8”

HCK4-4

1” (25)

1”

3/4”, 1-1/4”

1-1/8”

HCK4-5

1-1/4” (32)

1-1/4”

3/4”, 1”

1-3/8”

HCK4-7

1-1/2” (40)

1-1/2”

2”

1-5/8”

HCK4-8

2” (50)

2”

1-1/2”

2-1/8”

HCK4-9

2-1/2” (65)

2-1/2”

3”

2-5/8”

HCK4-0

3” (80)

3”

3-1/8”

HCK4-1

4” (100)

4”

4-1/8”

HCK4-2 close-couples to HS6 & HS8 Solenoid Valves.
HCK4-3, -4, & -5 close-couples to HS7 Solenoid Valve.
FPT available only 3/8” to 1¼”.

TO ORDER:  Specify valve type, connection style and 

size, and close-coupling information if needed.

TYPICAL SPECIFICATIONS

“Refrigeration  in-line  check  valves  shall  have  steel 

or  ductile  iron  bodies,  stainless  steel  seat  discs, 
stainless steel closing springs, and be suitable for a 
safe working pressure of 400 psig, as manufactured 

by  Hansen  Technologies  Corporation  type  HCK4  or 

approved equal.”

HCK4

ADAPTER RING

TYPICAL CLOSE-COUPLING TO SOLENOID VALVE