Start-up
Page GB-19
■
The refrigerant is fl ammable when
spurting out and can damage the
eyes. If this happens, rinse eyes with
clean water and seek medical assis-
tance immediately.
■
To prevent the formation of an ignit-
able gas-air mixture in the event of a
leak in the refrigeration circuit, the in-
stallation space must have a minimum
size of 1 m³ per 8 g of refrigerant in
compliance with the standard EN 378.
The amount of refrigerant contained
in your appliance can be found in
the data sheet at the end of the user
manual.
NOTICE
Risk of damage!
The appliance may not operate proper-
ly if exposed to low ambient tempera-
tures for extended periods of time. This
can then lead to an increase in temper-
ature inside the appliance.
■
Always abide by the prescribed am-
bient temperature (see the “Climate
class” line on page GB-28).
C
B
A
D
E
Space requirement according to appliance
dimensions
A:
54.5 cm
B:
107 cm
C:
91.5 cm
D:
≥ 5.0 cm
E:
110-125°
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 3 m³.