5
Hot tub performance parameters
1 Hot tub performance parameters
1.1
Performance parameters of CELTIC SPAS hot tubs
Performance parameters
rated voltage:
three-phase 230/400 V 50 Hz*
maximum working current:
3× 16 A
current surge:
up to 3× 25 A
voltage resistance:
1 250 V/min. without breakdown
insulation resistance:
>= 1 M Ω
water resistance (cover):
IPX5
protection against electric shock:
first stage
T he product does not use the 400 V phase to phase voltage. It is possible to adjust
it to 1× 230 V, however, this is not recommended due to limitations of the functions.
(For more information on this connection, please refer to the Supplements, p. 22)
Load capacity
heating:
1× 230 V/3 kW/13.6 A
ozone:
1× 230 V/50 – 60 Hz/80 mA
blower:
1× 230 V/0.66 kW/2.9 A
pump 1/2:
0.42/2.2 kW
total input power (depending on type of hot tub):
6 kW/h
protection class:
I.
lighting:
LED 12 V alternating /10 W
maximum output power:
20 W
moisture resistant speakers:
according to equipment
Preparation and electrical connection options – AC three-phase
current 3× 230/400 V/16 A/20 A
Ensure that the hot tub is always connected to a circuit protected by a residual-current
protector with a residual current of 0.03 A. It is necessary to use a Type C or Type D
For your own safety and the safety of your product, please observe the following
instructions. Read the following information carefully and follow the user manual
exactly when using the hot tub to avoid damaging the product or the risk of injury.
This appliance is intended for use by children 8 years of age or older with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
provided they are under supervision or have been instructed on the use of the
product and understand the risks. Children must not play with the product.
Cleaning and maintenance must not be performed by children without supervision.
Содержание IN.K300
Страница 1: ...USER MANUAL IN K300 ...