Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible - thermo cartridge calcified
- Exchange thermo cartridge
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Install function block turned
through 180º
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button,
exchange if necessary
Valve stiff
- Shut-off unit damaged
- Exchange shut-off unit
Shower or spout dripping
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
Содержание PuraVida 15775403
Страница 6: ...6 2 3 1 X 11 3 2 4 1 2 5 X 1 2 mm SW 4 mm 5 Nm 1 silicone iBox universal 01800180...
Страница 7: ...7 9 8 6 7 0 1 Nm 11 10 SW 3 mm 4 Nm SW 2 mm 4 Nm 1 2 3 silicone silicone...
Страница 8: ...8 1 2 1 2 3 SW 3 mm...
Страница 9: ...9 5 6 7 8 z B 42 C for example 42 C 3 4 1 1 2 2 SW 3 mm 4 Nm SW 2 mm 4 Nm...
Страница 10: ...10 1 2 3 4 1 2 3 4 SW 4 mm 5 6 SW 27 mm 7 SW 2 mm SW 3 mm...
Страница 11: ...11 SW 2 mm 4 Nm SW 4 mm 5 Nm 13 10 11 12 4 3 2 1 SW 3 mm 4 Nm 8 rot red 9 SW 27 mm 8 Nm...
Страница 12: ...12 40 C 1 2 open ffnen close schlie en hot warm cold kalt...