6
English
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from
using this product.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• If the thermostat or mixer is set to maximum water
temperature, there is a risk of scalding at hydraulical
opening of the check valve. For this reason,
Hansgrohe recommends that you set up the "Safety
Function".
Special information for UK
If installing this product with a pump, please be aware
that it has to have negative head switching. This product
will not function with a positive head pump.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking
water!
• Thermostat Highflow for 1 consumer (at the bottom)
and one additional consumer (on top)
Symbol description
Do not use silicone containing acetic acid!
Installation example
(see page 8)
Adjustment
(see page 16)
After the installation, the output temperature of the
thermostat must be checked. A correction is necessary if
the temperature measured at the output differs from the
temperature set on the thermostat.
Safety Function
(see page 16)
The desired maximum temperature for example max.
42º C can be pre-set thanks to the safety function.
Maintenance
(see page 18)
• The check valves must be checked regularly
according to EN 806-5 in accordance with national
or regional regulations (at least once a year).
• To guarantee the smooth running of the thermostat, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Dimensions
(see page 21)
Flow diagram
(see page 21)
free flow
Outlet 1
Outlet 2
Spare parts
(see page 22)
Special accessories
(see page 22)
order as an extra
• extension 25 mm #13595000
• Extension Set 22 mm (when wall is not deep
enough) #13593000
• levelling set 1° #95521000
• nut + flange #92696000
Cleaning
(see page 23)
Operation
(see page 20)
Minor leaking may occur briefly during initial commis-
sioning and interruption/restart of the water supply.
Test certificate
(see page 23)
i
+
Содержание Picta Select 13752000
Страница 9: ...9 SW 5 mm 2 1 2 1 01800180 SW 4 mm 5 Nm 2 3 SW 4 mm 1 1 2 mm 1 2 3 4 5 6...
Страница 10: ...10 1 2 0 mm 0 mm 7 8 9...
Страница 11: ...11 1 2 3 SW 4 mm 1 2 SW 10 mm 2 Nm X 1 2 mm Silicone 10 11 12 13 14...
Страница 12: ...12 0 1 Nm 1 2 1 2 X 11 Silicone 15 16 17 18 19 20...
Страница 13: ...13 40 C 40 C 2 1 40 C 1 2 40 C SW 3 mm 2 Nm 40 C CLICK 21 22 23 24 25 26...
Страница 14: ...14 40 C 1 2 0 mm A 0 mm 40 C 40 C 40 C 27 A B C D E...
Страница 15: ...15 0 SW 4 mm 5 Nm 40 C max 5 SW 4 mm 1 2 7 mm 28 C A B...
Страница 16: ...16 40 C 2 1 1 2 40 C 40 C 40 C 1 2 3 SW 3 mm...
Страница 17: ...17 40 C SW 3 mm 2 Nm 1 CLICK 40 C 2 1 7 8 5 6 2 z B 42 C for example 42 C 3 4 2 1...
Страница 18: ...18 40 C SW 4 mm 40 C 2 1 2 3 4 5 6 SW 24 mm 1...
Страница 19: ...19 SW 24 mm 15 Nm 40 C 40 C rot rouge red 7 8 0 1 Nm 9 10 11 12 CLICK 1 2 SW 4 mm 5 Nm...
Страница 20: ...20 40 C 40 C 40 C 40 C 1 2 40 C schlie en ferm close ffnen ouvert open warm chaud hot kalt froid cold...