Assembly see page 31
Fault
Cause
Remedy
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective, sedimentation
-
Exchange cartridge
Diverter not operating
-
Residue
-
Clean converter / grease O-rings
-
Water pressure to low
-
Increase water pressure
-
Diverter defective
-
Exchange diverter
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
-
Hot water limiter incorrectly set
-
Set hot water limiter
-
Crossflow
-
Exchange cartridge
Test certificate
(see page 44)
Spare parts
(see page 38)
Cleaning
see enclosed brochure.
Maintenance
(see page 36)
14146XXX / 14466XXX/ 14477XXX /
15447XXX / 31466000 / 31476000 /
31486XXX / 31487000 / 31646000 /
31946000 / 32477000: The safety device
must be checked regularly according to DIN
EN 1717 in accordance with national or
regional regulations (at least once a year).
Operation
(see page 42)
Flow diagram
(see page 35)
c
Shower outlet
d
Tub outlet
Dimensions
(see page 34)
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 33. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms.
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
14146XXX / 14466XXX/ 14477XXX / 15447XXX /
31466000 / 31476000 / 31486XXX / 31487000 /
31646000 / 31946000 / 32477000: Safety against
backflow
The product is exclusively designed for drinking water!
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
English