Assembly see page 8
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
The fitting must be installed, flushed and tested after
the valid norms.
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15 MPa.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
150 ±12mm
Connections G 1/2:
cold right - hot left
anti-pollution function
•
•
English
Spare parts
(see page12)
Dimensions
(see page 10)
Do not use silicone containing acetic acid!
Operation
(see page 13)
Maintenance non return valve
(see page 14)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
Symbol description
Flow diagram
(see page 10)
Bath tub
Shower
Cleaning
see enclosed brochure.
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 11. No adjustment
is necessary when using a continuous flow
water heater.
Содержание Metropol Puro 33144007
Страница 7: ......
Страница 8: ...Silicone 1 2 4 5 2 1 2 1 2 1 6 3 max 36 mm max 5 mm min 32 mm...
Страница 9: ...7 SW 30 mm 20 Nm...
Страница 10: ...10 Metropol Puro 33144007 218 150 209 12...
Страница 11: ...11 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa...
Страница 13: ...13 ffnen open schlie en close warm hot kalt cold schlie en Brause close shower ffnen Brause open shower...
Страница 14: ...14 1 2 4 3...