Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
Fault
Cause
Remedy
Insufficient water
-
check valve hasn't moved back
-
Exchange check valves
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low
-
Hot water limiter incorrectly set
-
Set hot water limiter
Instantaneous heater didn’t work
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
-
check valve hasn't moved back
-
Exchange check valves
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 6)
To adjust the hot water limiter. Using a
hot water limiter in combination with
a continuous flow water heater is not
recommended.
Operation
(see page 7)
Cleaning
(
see enclosed brochure)
Maintenance
(see page 8)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Dimensions
(see page 9)
Flow diagram
(see page 9)
Spare parts
(see page 11)
2
Содержание Logis 71400009
Страница 4: ...4 5 1 3b 2 4 3a 1 2 1 2 Silicone 1 2 min 35 mm max 39 mm max 5 mm SW 24 mm...
Страница 5: ...5 6 7 8 1 3 2 SW 22 mm 2 min SW 22 mm 2 Nm Logis 71400009 71400019 71400029 SW 30 mm 17 Nm...
Страница 6: ...6 Justierung 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa...
Страница 7: ...7 close schlie en open ffnen open ffnen hot warm cold kalt 1 2...