Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
• The product is exclusively designed for drinking
water!
• Safety against backflow
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 37)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance
(see page 40)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 38)
Flow diagram
(see page 39)
Spare parts
(see page 41)
XXX= Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Special accessories
(order as an extra)
Adapter (G⅜ / G½)
#93395000 (see page 41)
Cleaning
(see page 35)
Operation
(see page 44)
Hansgrohe recommends not to use as drinking water the
first half liter of water drawn in the morning or after a
prolonged period of non-use.
Test certificate
(see page 44)
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping at the threaded base - connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter