background image

16

Trouble Shooting 

Fault

Cause

Remedy

Insuffient water flow

-  Supply pressure inadequate

-  Shower filter seal dirty 

-  Thermostat cartridge filters dirty

-  Check mains pressure

-  Clean filter seal between 

shower and hose

-  Remove cartridge & clean the 

filters on the barrel

,Crossflow‘, hot water is forced 

into cold water pipe, or vice 

versa

-  check valves dirty or leaking

-  Clean check valves -  

replace if necessary

Spout temperature does not corre-

spond wlth the temperature set

-  Thermostat has not been 

adjusted

-  Hot water temperature too low

-  Calibrate thermostat 

-  Increase hot water temperature 

No temperature control

-  Thermostat cartridge failure or 

blocked filters

-  Check/clean filters 

-  Replace cartridge 

Shower or spout dripping

-  Dirt in the flow valve or ‚shut 

off‘ unit damaged

-  Clean or replace shut-off unit 

Warranty 

You have purchased a quality product from Hansgrohe. All parts which show any kind of fault as far as 

construction, material or assembly are concerned within the first 24 months after installation, we will repair 

or exchange the part in question free of charge. Faulty items become our property. 

We do not grant warranty for faults caused by:

 

unsuitable or improper use; incorrect assembly; installation started and/or completed by a non-qualified 

plumber, natural wear out, improper or careless treatment, lack of maintenance; unsuitable usage; 

chemical, electro-chemical or electrical influences.

Hansgrohe · Postfach 1145 · D-77761 Schiltach · T49 (0)  78 36/51-1282 · T49 (0)  7836/511440

E-Mail: [email protected] · Internet: www.hansgrohe.com 

10/2011 9.04190.03

Technical Hotline 

E-mail

0 870  7701975

 [email protected]

Содержание Ecostat S 15715000

Страница 1: ...Telefon 04621 30 60 89 0 Mail info unidomo com ffnungszeiten Mo Fr 8 00 17 00 Uhr a member of DAIKIN group Individuelle Beratung Komplettpakete Kostenloser Versand ber 15 Jahre Erfahrung Hochwertige...

Страница 2: ...Installation Instructions Ecostat S 15715000...

Страница 3: ...10 In service tests 11 Frequency of in service tests 11 Thermostatic Adjustement Temperature Limitation 12 Callibrating Thermostat 12 Setting Thermostat Max Temp 13 Operating your Shower 14 Cleaning...

Страница 4: ...hanical Services Contractors NAPH MSC England Wales Water Industry Approved Plumber Scheme WIAPS Dispose of plastic bags carefully Keep children well away from the work area Check for hidden pipes and...

Страница 5: ...ase check that you have been supplied with the following 1 3 2 4 5 6 9 7 8 1 Handle 2 Face plate 3 Sleeve 4 Fixing screws 5 Fixing plate 6 thermostat cartridge block 7 spindle extension 8 Allen screw...

Страница 6: ...tions cannot be guaranteed to operate as a TMV2 or TMV3 valve Recommended outlet temperatures The BuildCert TMV scheme recommends the follow ing set maximum mixed water outlet temperatures for use in...

Страница 7: ...point 1 0 10 bar Unvented System pressure balanced 1 0 10 bar Pumped System 1 0 10 bar IMPORTANT If you install this mixer with a gravity fed system there must be a minimum head vertical distance fro...

Страница 8: ...7 Unvented System pressure balanced Pumped System...

Страница 9: ...ithin 2mm of the tiles fig 1 1 2 3 3 Fit the the thermostat cartridge into the I Box using 4 allen bolts Ensure the hot red mark is on the left and the cold blue mark is on the right fig 3 2 Unscrew t...

Страница 10: ...fig 4 5 4 6 6 Push fit the spindle extension and handle and fix in place with the 35mm allen screw fig 6 5 Push the sleeve onto the thermostat cartridge ensuring the notch on the sleeve is in the 12 o...

Страница 11: ...rate which shall be measured d isolate the cold water supply to the mixing valve and monitor the mixed water temperature e record the maximum temperature achieved as a result of d and the final stabi...

Страница 12: ...nce of any other instruction or guidance on the means of determining the appropriate frequency of in service testing the following procedure may be used 1 6 to 8 weeks after commissioning carry out th...

Страница 13: ...thermostatic mixer valve should be checked annually by a qualified person to ensure correct operation The mixer is fitted with check valves page 15 pos 9 and filters on the thermostatic element page 1...

Страница 14: ...dle and slide off the locking ring fig 3 4 Turn the spindle until the required maximum temperature is reached 43 C You will need to use a thermometer fig 4 5 Replace the locking ring back onto the spi...

Страница 15: ...lowing points Clean the mixers and showers as and when required The cleaning dosage and time the cleaner needs to take effect should be adjusted according to the product and the cleaner should not be...

Страница 16: ...kit 1 Handle for thermostatic element 38391000 2 Cover plate 98981000 3 Sleeve 97439000 4 Fixing screws 96454000 5 Fixing plate 98793000 6 Thermostatic element 96633000 7 Filter 97367000 8 Check valve...

Страница 17: ...ng Dirt in the flow valve or shut off unit damaged Clean or replace shut off unit Warranty You have purchased a quality product from Hansgrohe All parts which show any kind of fault as far as construc...

Отзывы: