English
Assembly see page 60
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Regulator filter dirty
-
Clean filter in front of the mixer and
on the MTC-thermo cartridge
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
Temperature regulator dirty or calci-
fied
-
Clean temperature regulator, ex-
change if necessary
-
For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
-
Install function block turned through
180º
Safety stop button not operating
-
Spring defective
-
push button calcified / contami-
nated
-
Clean spring and/or button, ex-
change if necessary
Special information for UK
(see page 69)
7
Содержание Ecostat E 15710000
Страница 60: ...60 X 1 2 mm Montage 2 1 2 Silikon 1 2 3 4 5 6 X 11 ...
Страница 61: ...61 Montage 7 PuraVida 15770XXX 8 9 3 SW 3 mm 4 Nm 0 1 Nm 1 2 Nr 10476220 Armaturenfett Grease ...
Страница 62: ...62 Safety Function Justierung 2 1 3 1 1 2 SW 4 mm 2 ...
Страница 63: ...63 Safety Function z B 42 C for example 42 C 2 1 1 2 3 4 5 6 7 8 ...
Страница 64: ...64 Wartung 1 1 2 2 2 3 4 5 6 SW 24 mm SW 4 mm SW 4 mm 1 ...
Страница 65: ...65 Wartung 7 8 9 10 11 SW 24 mm 15 Nm 1 2 1 2 SW 4 mm 5 Nm ...
Страница 75: ...75 ...