Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Filters are dirty (#96922000)
-
Clean filter in front of the mixer
and on the MTC-thermo cartridge
(#96922000)
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
Shower or spout dripping
-
Dirt or sedimentation on valve seat,
shut-off unit damaged
-
Clean or exchange shut-off unit
Instantaneous heater didn't work with
thermostat
-
Ecostop safety set removed.
(#95042000)
-
Remove Ecostop safety set
(#95042000)
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Filters are dirty
-
Clean the filter / exchange filter
-
check valve hasn't moved back
-
Exchange check valves
Assembly see page 20
Flow diagram
(see page 22)
Operation
(see page 27)
Dimensions
(see page 22)
Cleaning
see enclosed brochure
5
Содержание Ecostat 1001 SL 13278000
Страница 20: ...20 Montage 5 1 3b 2 4 3a 1 2 1 2 Silicone 1 2 min 34 mm max 39 mm max 5 mm SW 24 mm...
Страница 21: ...21 Montage 6 7 SW 30 mm 17 Nm 97510000...
Страница 23: ...23 Justierung SW 3 mm SW 3 mm 2 Nm 1 3 4 2 5 6...
Страница 24: ...24 ECOSTOP 10 l min SW 3 mm SW 3 mm 2 Nm 1 3 4 2 5 6...
Страница 25: ...Safety Function 1 4 6 5 1 2 SW 3 mm z B 42 C for example 42 C 2 3 1 2 SW 3 mm 2 Nm...
Страница 26: ...26 Wartung 1 2 3 SW 30 mm 1 2 SW 10 mm 4 5 SW 10 mm 20 Nm 6 7 1 2 SW 30 mm 17 Nm...