22 (16)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from
using this product.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The product is not designed to be used with steam
baths!
Assembly
(see page 6)
Pressure and permeability test
The connections of the thermostatic mixer should be
tested regular after installation.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar ≈ 147 PSI)
Hot water temperature:
max. 60°C
Centre distance:
160 mm
Connections M 26x1,5:
cold right - hot left
Thermal disinfection:
70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking
water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 7)
After the installation, the output temperature of the
thermostat must be checked. A correction is necessary if
the temperature measured at the output differs from the
temperature set on the thermostat.
Safety Function
(see page 8)
The desired maximum temperature for example max.
42º C can be pre-set thanks to the safety function.
ECOSTOP
(see page 9)
Maintenance
(see page 10)
The mixer is equipped with check valves. The check
valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
To guarantee the smooth running of the thermostat, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Operation
(see page 12)
Dimensions
(see page 14)
Flow diagram
(see page 14)
Shower outlet
Tub outlet
Spare parts
(see page 15)
Cleaning
(see page 16)
Test certificate
(see page 11)
English
Содержание Ecostat 1001 CL 13218000
Страница 7: ...7 3 mm 3 mm 1 3 4 2 5 6 7 16...
Страница 8: ...8 1 2 3 mm for example 42 C till exempel 42 C 1 2 3 mm 1 4 6 5 2 3 8 16...
Страница 9: ...9 3 mm for example 10 l min till exempel 10 l min SW 3 mm 1 2 4 3 5 6 9 16...
Страница 10: ...10 6 mm 23 mm 6 mm 1 2 1 2 3 4 5 6 10 16...
Страница 12: ...12 open ppna hot varmt cold kallt close st nga Ecostat 1001 CL 13218000 1 2 1 40 C 2 12 16...
Страница 13: ...13 Ecostat 1001 CL 13217000 open ppna hot varmt cold kallt close st nga 1 2 1 40 C 2 50 100 13 16...