Hans Grohe Ecostat 1001 CL 13218000 Скачать руководство пользователя страница 2

22 (16)

 

Safety Notes

 

Gloves should be worn during installation to prevent 

crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 

and body cleaning purposes.

 

Children as well as adults with physical, mental and/

or sensoric impairments must not use this product 

without proper supervision. Persons under the 

influence of alcohol or drugs are prohibited from 

using this product.

 

The hot and cold supplies must be of equal 

pressures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 

surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

• The product is not designed to be used with steam 

baths!

Assembly 

(see page 6)

Pressure and permeability test

The connections of the thermostatic mixer should be 

tested regular after installation.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar ≈ 147 PSI) 

Hot water temperature: 

max. 60°C 

Centre distance: 

160 mm 

Connections M 26x1,5: 

cold right - hot left 

Thermal disinfection: 

70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking 

water!

Symbol description

Do not use silicone containing acetic acid!

Adjustment 

(see page 7)

After the installation, the output temperature of the 

thermostat must be checked. A correction is necessary if 

the temperature measured at the output differs from the 

temperature set on the thermostat.

Safety Function 

(see page 8)

The desired maximum temperature for example max. 

42º C can be pre-set thanks to the safety function.

ECOSTOP 

(see page 9)

Maintenance 

(see page 10)

 

The mixer is equipped with check valves. The check 

valves must be checked regularly according to 

EN 806-5 in accordance with national or regional 

regulations (at least once a year).

 

To guarantee the smooth running of the thermostat, it 

is necessary from time to time to turn the thermostat 

from total hot to total cold.

Operation 

(see page 12)

Dimensions 

(see page 14)

Flow diagram 

(see page 14)

  Shower outlet

  Tub outlet

Spare parts 

(see page 15)

Cleaning 

(see page 16)

Test certificate 

(see page 11)

English

Содержание Ecostat 1001 CL 13218000

Страница 1: ...Flow diagram 14 Spare parts 15 Cleaning 16 Contact information 16 SV Inneh llsf rt ckning 1 Bruksanvisning Monteringsanvisning 4 Fels kning 5 Montering 6 Inst llning av maxtemperatur 7 Safety Functio...

Страница 2: ...ended operating pressure 0 1 0 5 MPa Test pressure 1 6 MPa 1 MPa 10 bar 147 PSI Hot water temperature max 60 C Centre distance 160 mm Connections M 26x1 5 cold right hot left Thermal disinfection 70 C...

Страница 3: ...ose Crossflow hot water being forced into cold water pipe or vice versa when mixer is closed Backflow preventers dirty or leaking Clean backflow preventers exchange if necessary Spout temperature does...

Страница 4: ...bar 147 PSI Varmvattentemperatur max 60 C Anslutningsm tt 160 mm Anslutningar M 26x1 5 kallt h ger varmt v nster Termisk desinfektion 70 C 4 min Sj lvsp rr mot terfl de Produkten r enbart avsedd f r...

Страница 5: ...kallvatten inloppet och vice versa Backventil r igensmutsad eller ot t Reng r backventil byt ut om n dv ndigt Den faktiska vatten temperaturen st mmer Inte verens med den Inst llda Termostaten st lld...

Страница 6: ...2 5 mm 23 mm 2 5 mm The nuts of the installation plate must be tightened to the manufacturer s instructions Muttrarna dras t enligt monteringsanvisningen fr n leverant ren av blandarf ste 1 2 3 4 5 6...

Страница 7: ...7 3 mm 3 mm 1 3 4 2 5 6 7 16...

Страница 8: ...8 1 2 3 mm for example 42 C till exempel 42 C 1 2 3 mm 1 4 6 5 2 3 8 16...

Страница 9: ...9 3 mm for example 10 l min till exempel 10 l min SW 3 mm 1 2 4 3 5 6 9 16...

Страница 10: ...10 6 mm 23 mm 6 mm 1 2 1 2 3 4 5 6 10 16...

Страница 11: ...3 mm 2 The nuts of the installation plate must be tightened to the manufacturer s instructions Muttrarna dras t enligt monteringsanvisningen fr n leverant ren av blandarf ste 13217000 X 13218000 X 7 8...

Страница 12: ...12 open ppna hot varmt cold kallt close st nga Ecostat 1001 CL 13218000 1 2 1 40 C 2 12 16...

Страница 13: ...13 Ecostat 1001 CL 13217000 open ppna hot varmt cold kallt close st nga 1 2 1 40 C 2 50 100 13 16...

Страница 14: ...6 160 G 1 2 4 2 M 2 6 x 1 5 58 79 2 4 24 17 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0...

Страница 15: ...29000 16x2 95835000 97367000 M5x5 2 5 mm 95433000 95433000 98674000 96737000 98137000 17x1 5 98213000 9x1 19 mm Ecostat 1001 CL 13217000 95835000 97367000 96737000 98137000 17x1 5 98213000 9x1 9812900...

Страница 16: ...nsgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendat...

Отзывы: