Safety and Important Information

Hansgrohe products are safe provided they are installed, 
used and maintained in accordance with these instructions 
and recornrnendations.

Please read these instructions thoroughly and retain for 
future use.

The  plumbing  installation  of  this  thermostat  mixing 
valvemust comply with the requirements of UK
Water Regulations/Bylaws (Scotland), Building Regulati-
ons or any other regulations specified by the local Water 
Authority and supplier.

The installation of thermostatic mixing valves must comply 
with the requirements of the Water Supply (Water Fittings) 
Regulations 1999.

We strongly recommend that you use a plumber registered 
with or a member of an Association:

Chartered Institute of Plumbing and Heating Engineering 
(CIPHE)
Water Industry Approved Plumber Scheme (WIAPS)

Dispose of plastic bags carefully

Keep children well away from the work area.

Check  for  hidden  pipes  and  cables  in  the  wall  before 
drilling holes.

The unit must be mounted on a finished waterproofed wall 
surface (usually tiles).

If you are using power tools (e.g. to drill holes) wear sa-
fety glasses and always disconnect tools from the power 
supply after use.

Do not operate the shower unit if the hand shower or spray 
hose has been damaged or is blocked.

Do not block the flow of water from the hand shower, by 
placing it on your hand or any other part of your body 
or foreign object.

The thermostatic unit should be serviced annually by a 
qualified person to ensure maximum safety during use.

The thermostatic mixing valve will be installed in such a 
position that maintenance of the TMV and its valves and the 
commissioning and testing of the TMV can be undertaken.

The  mixer  is  fitted  with  check  valves  (page  67  pos. 
94074000). There are filters on the thermostatic element 
too (page 67 pos. 94282000).

The fitting of isolation valves is required (preferred location 
page 71 Installation Requirements)

On the following pages 14 - 19 you 

can find important information only for 

the installation in UK

Technical Hotline for UK only 

01372465655

E-mail for UK only 

[email protected]

(Diese Servicehotline ist nur für das Vereinigte König-
reich Großbritannien, nicht z. B. für Deutschland)

Содержание Ecomax 14243000

Страница 1: ...EN Instructions for use assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 4 Ecomax 14243000...

Страница 2: ...utting injuries The shower system may only be used for bathing hygienic and body cleansing purposes Children as well as adults with physical mental and or sensoric impairments must not use this shower...

Страница 3: ...necessary Spout temperature does not cor respond with temperature set Thermostat has not been adjusted Hot water temperature too low Adjust thermostat Increase hot water temperature to 42 C to 65 C T...

Страница 4: ...r Trinkwasser konzi piert Sicherheitshinweise Bei der Montage m ssen zur Vermeidung von Quetsch und Schnittverletzungen Handschuhe getragen werden Das Produkt darf nur zu Bade Hygiene und K rper reini...

Страница 5: ...r stimmt nicht mit der eingestellten Temperatur berein Thermostat wurde nicht justiert Zu niedrige Warmwassertempe ratur Thermostat justieren Warmwassertemperatur erh hen auf 42 C bis 65 C Temperaturr...

Страница 6: ...6 SW 30 mm 17 Nm SW 30 mm 17 Nm 2b 1 2a...

Страница 7: ...7 SW 3 mm 2 Nm SW 3 mm 42 40 1 2 3 4 5 6...

Страница 8: ...8 1 2 3...

Страница 9: ...9 close schlie en 90 open ffnen 1 2 cold kalt 40 C hot warm 90...

Страница 10: ...10 SW 30 mm SW 12 mm 2 1 2 3 4 1...

Страница 11: ...11 Ecomax 14243000...

Страница 12: ...12 96922000 97210000 97163000 97164000 98870000 95589000 92929000 96488000 97211000 98163000 15x2 98194000 28x2 96644000 A 96633000 Ecomax 14243000 PA IX DVGW SVGW ACS WRAS ETA KIWA 14243000 X...

Страница 13: ...g recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation EN Cleaning recommendation Warranty Contact DE Reinigungs...

Страница 14: ...waterproofed wall surface usually tiles If you are using power tools e g to drill holes wear sa fety glasses and always disconnect tools from the power supply after use Do not operate the shower unit...

Страница 15: ...allowable temperature tolerances inherent in thermo static mixing valves and temperature losses in metal baths It is not a safe bathing temperature for adults or children The British Burns Association...

Страница 16: ...16 KEY Isolating valve Reducing valve Mixer Valve Pump Gas Combination Boiler multi point Unvented System pressure balanced Pumped System...

Страница 17: ...priate at commissioning to carry out some simple checks and tests on each mixing valve to provide a performance reference point for future in service tests Procedure 1 Check that a the designation of...

Страница 18: ...ce of any other instruction or guidance on the means of determining the appropriate frequency of in service testing the following procedure may be used 1 6 to 8 weeks after commissioning carry out the...

Страница 19: ...after correct installation the outlet temperature of the water can never exceed 43 C To guarantee a smooth running of the thermostatic element it is necessary from time to time to turn the thermostat...