6
7
Important!
The fitting must be installed, flushed
and tested after the valid norms.
Technical Data
Operating pressure: max. 10 bars
Recommended operating pressure: 1 - 5 bars
Test pressure: 16 bars
Hot water temperature: max. 80° C
Recommended hot water temp.: 65° C
Rate of flow by 3 bars: approx. 22 l/mint
Hansgrohe mixers can be used together with hydrau-
lically and thermically controlled continuous flow
heaters if the flow pressure is at least 1.5 bars.
Spare parts
(see page 3)
1 flange
94135000
2 S - unions
94140000
3 shut off unit
94142000
4 handle for cold water
12193000
4.1 screw cover for cold/hot water 96407000
5 handle for hot water
12194000
6 aerator cpl. (10)
96406000
7 selector assy
96418000
8 selector
96417000
9 aerator cpl. (10)
13485000
English
Attenzione:
la rubinetteria deve essere installata,
pulita e testata secondo le istruzioni riportate!
Dati tecnici
Pressione d’uso: max. 10 bar
Pressione d’uso consigliata: 1 - 5 bar
Pressione di prova: 16 bar
Temperatura dell’acqua calda: max. 80° C
Temp. dell’acqua calda consigliata: 65° C
Portata di erogazione: 22 l/min 3 bart
I miscelatori Hansgrohe possono venire usati con
caldaie a “bassa pressione” se la pressione di flusso
è almeno di 1,5 bar.
Parti di ricambio
(vedi pagg. 3)
1 rosetta
94135000
2 raccordi eccentrici
94140000
3 cartuccia
94142000
4 manopola acqua fredda
12193000
4.1 tappino acqua fredda / calda 96407000
5 manopola acqua calda
12194000
6 rompigetto compl. (10)
96406000
7 deviatore compl.
96418000
8 deviatore
96417000
9 rompigetto compl. (10)
13485000
Italiano
Содержание Duo Classic 12401000
Страница 3: ...2 12401000 1245100 12601000 12611000 12616000...
Страница 4: ...3 6 6 4 3 4 1 6 5 1 2 9 8 7 3 7 4 4 1 1 2 5...
Страница 5: ...4...
Страница 15: ...14...