English
Assembly see page 34
Technical Data
Operating pressure:
max.1 MPa
Recommended operating pressure:
0,15 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
150±12 mm
Connections G 1/2:
cold right - hot left
anti-pollution function
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
The fitting must be installed, flushed and tested after
the valid norms.
Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer’s indications of the dowel
manufacturer have to be taken into account.
The filter insert (97708000) must be used to ensure
the standard flow rate and to protect the hand
shower against incoming dirt by pipework. Do you
want a larger water flow rate, then you must use the
filter packing (94246000) instead of the filter insert
(97708000). Incoming dirt leads to defects or/and
can damage parts of the hand shower; such caused
faults voids all liability and guarantee claims.
•
•
•
Symbol description
Do not use silicone containing acetic acid!
Maintenance
(see page 40)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional regula-
tions (at least once a year).
Spare parts
(see page 44)
Dimensions
(see page 32)
Flow diagram
(see page 33)
Operation
(see page 38
To adjust the hot water limiter on single lever
mixers, please see page 31. No adjustment
is necessary when using a continuous flow
water heater.
Cleaning
(see page 41) enclosed
brochure
4
Содержание Croma Showerpipe 27201000
Страница 31: ...31 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa 0 3 0 3...
Страница 32: ...32 Croma Showerpipe 27201000 27202000...
Страница 33: ...33 Croma Showerpipe 27201000 1 2 3 4 1 2 Croma Showerpipe 27202000 1 2 3 4 1 2...
Страница 34: ...34 Silicone 1 2 min 32 mm 2a 2b 98681000 max 37 mm max 5 mm 1 2 1 2...
Страница 35: ...35 3 4 5 6 2 1 7 8 1 2...
Страница 36: ...36 9 10 11 12 S i l i c o n e 13a 2 1...
Страница 37: ...37 SW 3 mm 14 13b S i l i c o n e 2 1 3 15 97708000 94246000...
Страница 38: ...38...
Страница 39: ...39...
Страница 40: ...40 3 4 2 SW 3 mm 1 2 1 3...
Страница 42: ...42 1 min 1 2 3 1 2 97708000 94246000...
Страница 43: ...43 1 2 3 1 2...