Attention!
The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water,
swivel to the right = cold water.
14450000: The flow is changed from bath to shower
function by pulling the knop at the upper side of the
spout. After shutting off the water flow, the mixer
returns automatically to the bath function.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
max. 80° C
Recommended hot water temp.: 65° C
Centre distance:
150 ± 16 mm
Connections G ½":
cold right -
hot left
Rate of flow 0,3 MPaes:
approx. 22 l/min
anti-pollution function
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled con-
tinuous flow heaters if the flow pressure is at least
0,15 MPa.
Attention!
The non return valves must be checked once a
year.
Spare parts
(see page 3)
1
handle
14894000
1.1 screw cover
96338000
2
flange
94192000
3
nut
94194000
4
cartridge cpl.
92730000
5
escutcheon
94135000
6
S - unions
94140000
7
aerator cpl.
13956000
8
selector
94077000
9
diverter knob
94078000
10 non return valve
94074000
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Filters dirty
- Non return ralve didn't move
back
- Clean filter seal between sho-
wer and hose
- Clean the filter/exchange filter
- Exchange non return valves
Mixer stiff
- Cartridge defective
- Exchange cartridge
Mixer dripping
- Cartridge defectiveSedimentati-
on
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incor-rectly set - Set hot water limiter
Instantaneous heater didn't work
- Flow limiter in handshower isn't
removed
- Filter are dirty
- Non return ralve didn't move
back
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves