Flow diagram
(see page 70)
Shower
Bath tub
Dimensions
(see page 69)
Operation
(see page 67)
Maintenance
(see page 65)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
• The mixer is equipped with non return
valves. The non return valves must be
checked regularly according to DIN EN
1717 in accordance with national or re-
gional regulations (at least once a year).
Adjustment
(see page 64)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Safety Function
(see page 63)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Do not use silicone containing acetic acid!
Symbol description
6
Safety Notes
6
Gloves should be worn during installation to prevent
crushing and cutting injuries.
6
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
6
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms!
• The product is not designed to be used with steam
baths!
Thermostatic mixer in conjunction with
combination boilers
• If fitting a hand shower remove the water limiter from
the shower.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5MPa
Test pressure:
1,6MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
• anti-pollution function
• The product is exclusively designed for drinking water!
English
6
Содержание AXOR Starck Organic 12410000
Страница 60: ...60 1 1 2 2 Silicone 1 2 150 12 SW 27 mm 3 4 5 6 38 38 ...
Страница 61: ...61 7 8 9 10 Ø 8 mm Silicone SW 10 mm SW 3 mm SW 3 mm 11 12 2 1 2 SW 3 mm 2 1 ...
Страница 62: ...62 13 14 15 16 2 2 2 1 1 1 SW 3 mm 3 Nm SW 3 mm 3 Nm ...
Страница 63: ...63 z B 42 C for example 42 C 2 1 SW 3 mm SW 3 mm 1 Nm 1 2 3 4 5 6 ...
Страница 64: ...64 1 4 2 3 ...
Страница 65: ...65 1 2 SW 3 mm 3 Nm 1 2 1 SW 3 mm 2 3 4 5 6 SW 22 mm SW 22 mm 4 Nm ...
Страница 66: ...66 2 1 SW 3 mm 3 Nm 2 1 SW 3 mm 3 Nm 7 8 9 10 ...
Страница 69: ...69 Starck Organic 12410000 Starck Organic 12602000 ...
Страница 70: ...70 Starck Organic 12410000 Starck Organic 12602000 2 1 ...