0 4
EN
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and⁄or
sensoric impairments must not use this product without
proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ If the thermostat or mixer is set to maximum water
temperature, there is a risk of scalding at hydraulical
opening of the check valve. For this reason, Hansgrohe
recommends that you set up the "Safety Function".
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C ⁄ 4 min
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
S A F E T Y F U N C T I O N (see page 12 )
The desired maximum temperature for example
max. 42º C can be pre-set thanks to the safety
function.
A D J U S T M E N T (see page 12 )
After the installation, the output temperature of
the thermostat must be checked. A correction is
necessary if the temperature measured at the
output differs from the temperature set on the
thermostat.
M A I N T E N A N C E (see page 14 )
⁄ The check valves must be checked regularly
according to EN 806-5 in accordance with
national or regional regulations (at least once
a year).
⁄ To guarantee the smooth running of the
thermostat, it is necessary from time to time to
turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 17)
F L O W D I A G R A M (see page 17)
free flow
Outlet 1
Outlet 2
S P A R E P A R T S (see page 18 )
XX = Colors
00 = Chrome Plated
34 = Brushed Black Chrome
67 = Matt Black
99 = Polished Gold-Optic
S P E C I A L A C C E S S O R I E S
(see page 18 )
order as an extra
⁄ extension 25 mm #13595000
⁄ Extension Set 22 mm (when wall is not deep
enough) 97407XX0, #98860XX0
⁄ levelling set 1° #95521000
⁄ nut + flange #92696000
C L E A N I N G (see page 20 )
O P E R A T I O N (see page 16 )
+
Содержание AXOR ShowerSelect Soft Cube 36707 7 Series
Страница 3: ...0 3 ZH 06 42 C 60 C 180 180 Select DN9 Select DN9 Select DN9 Select DN9 7 07 10...
Страница 6: ...0 6 SW 4 mm SW 4 mm 5 Nm Armaturenfett Grease 3 1 2 2 1 1 2 01700187 1 2 1 2 3 4 5 6 SW 5 mm 1 2 mm...
Страница 7: ...0 7 SW 4 mm 1 2 0 mm 0 mm 7 8 9 10...
Страница 8: ...0 8 X 11 X 1 2 mm 0 1 Nm SW 10 mm 2 Nm 11 12 13 14 15 16...
Страница 9: ...0 9 C 40 1 2 40 C 1 2 C 40 1 2 2 1 1 2 17 18 19 20 21 22...
Страница 10: ...1 0 0 mm A 0 mm C 40 1 2 CLICK 23 24 40 C 40 C A B C 3 2 2 1 1 SW 3 mm SW 3 mm 1 Nm C 40 40 C D E CLICK...
Страница 11: ...11 40 C max 5 25 0 SW 4 mm 5 Nm SW 4 mm 7 mm 1 2 A B C D...
Страница 12: ...1 2 42 C for example 42 C 2 1 1 2 SW 3 mm 1 2 40 C 40 C 40 C 40 C 1 CLICK 2 1 2 3 4 1 2 3...
Страница 13: ...1 3 2 1 C 40 1 2 40 C 1 2 CLICK 1 2 SW 3 mm 1 Nm 5 6 7 8 9...
Страница 14: ...1 4 SW 27 mm C 40 2 3 1 SW 4 mm 1 3 5 2 4 6...
Страница 15: ...1 5 red SW 4 mm 5 Nm SW 27 mm 8 Nm 40 C 40 C CLICK 2 1 3 0 1 Nm 7 9 11 8 10 12...
Страница 16: ...1 6 40 C 1 2 40 C 40 C 40 C 40 C...
Страница 20: ...2 0 AXOR AXOR www hansgrohe int com guarantee Q U I C K C L E A N QuickClean...
Страница 22: ...2 2...
Страница 23: ...2 3...