Assembly see page 60
Fault
Cause
Remedy
Insufficient water
- Shower filter seal dirty
- Clean filter seal between shower
and hose
- Non return valve hasn’t moved
back
- Exchange non return valves
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Instantaneous heater didn’t work
- Flow limiter in handshower isn’t
removed
- Remove flow limiter
- Filters are dirty
- Clean the filter / exchange filter
- Non return valve hasn’t moved
back
- Exchange non return valves
English
7
Содержание Axor Massaud 18450000
Страница 60: ...60 1 2 3 4 Silikon 1 2 3 1 2 3 4 ...
Страница 61: ...61 2 1 3 4 5 6 7 60 C 10 C 0 3 MPa 0 3 МПа 0 3 ﻣﻴﺠﺎﺑﺴﻜﺎل ...
Страница 62: ...62 Massaud 18450000 ...
Страница 63: ...63 97686000 18950000 ...
Страница 66: ...66 1 2 1 2 3 1 2 ...
Страница 67: ...67 2 1 3 1 min 2 1 1 2 ...
Страница 71: ...71 ...