![Hans Grohe AXOR Citterio/Uno2 Series Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/hans-grohe/axor-citterio-uno2-series/axor-citterio-uno2-series_instructions-for-use-assembly-instructions_594247004.webp)
4
0, 1, 2
Assembly see page 34
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
Electrical connection
The installation and testing work must be performed by a skilled electrician in
observance of VDE 0100 part 701 and IEC 60364-7-701.
The current version of the applicable regulations from VDE, local authorities
and utility companies must be observed for electric installation work.
The entire power is supplied via a 240V/N/PE/50Hz AC connection.
The system must be protected via a leakage current protective device (RCD/
FI) with a measurement difference current of ≤ 30 mA.
The proper function of this fusing/protection must be checked at regular inter-
vals.
The ambient temperature must not be higher than 50ºC.
It must be ensured that the product can be disconnected from the mains, e.g.
via a an all-pin switch as per EN 60335-1, sect. 24.3
Installation Instructions
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards. (Installation to EN 1717)
• Any work may only be carried out in a de-energized state.
• The basic body 01850180 can only be installed vertically!
• To turn in the supply pipes or to adjust the installation ring, fix the iBox with a
pipe in the vice. (see page 36)
• For the transformer supplied with the ready-to-use set, a flush-mounted outlet
socket with a 230 V supply line must be provided.
• The transformer must not be installed in protection zones 0, 1 or 2. (see page 33)
• The flush-mounted outlet socket is connected with the basic set via an empty
conduit EN 20.
• The clearance between flush-mounted outlet socket and basic set may amount to
max. 7 m
• This empty pipe must be affixed at least every 500 mm and the bending radius
must be greater than 100 mm.
• Up to four fittings can be connected to a transformer on a ready-to-use set
• All components must remain accessible.
• The gasket is not suitable for hot glue. If the iBox universal should be hot glued,
please take care that the mixer is not damaged.
• The iBox can depending on the building application be mounted in different
ways, Installation examples please see page 34 and 35.
A
Direct wall installation.
B
Direct wall installation with 10 mm adjustable mounting studs.
C
Installation on carrier system.
D
Installation on prefabricated house installation panels or finished cells.
E
Brick wall installation.
Flush piping system
Flush the complete installation (both hot and cold water supply) acc. to DIN 1988 /
EN 1717. The arrows on the flush body are indicating which inlet is connected with
which outlet line, e.g. cold water suply with bottom outlet and hot water supply with
top outlet. As only one outlet is required, the flush body must be turned by 90º after
the first flushing.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 65°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
transformer
Empty pipe
230 V
Dimensions
(see page 32)
English
Operation
(see page 39)
Spare parts
(see page 31)
Water connection DN20 Cold water
Special accessories
(order as an extra)
extension 25 mm #13594000 (see page 31)
6 V
Water connection DN20 Warm water
Protected area
(see page 33)
Test certificate
(see page 40)
Содержание AXOR Citterio/Uno2 Series
Страница 32: ...Citterio 39117000 Uno 38119000 Citterio 39118000 Uno 38120000 Maße 32 ...
Страница 34: ...34 B A 140 2 2 0 140 2 2 0 Montage ...
Страница 35: ...C E D Montage 35 ...
Страница 36: ...1 2 3 2 3 4 1 Ø 16 mm Montage Schraubstock 36 ...
Страница 37: ...5 6 7 8 9 Montage 37 ...
Страница 38: ...PCI Lastogum II III I Silikon Montage 38 ...