0 5
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
The product may only be used for bathing, hygienic and body cleaning purposes.
Children may only use the product unsupervised if they have been suitable
instructed and trained to use the product safely and to understand the risks of
improper operation.
E L E C T R I C A L C O N N E C T I O N
The installation and testing work must be performed by a skilled electrician in
observance of VDE 0100 part 701 and IEC 60364-7-701.
The current version of the applicable regulations from VDE, local authorities and
utility companies must be observed for electric installation work.
The entire power is supplied via a 240V⁄N⁄PE ⁄50Hz AC connection.
The system must be protected via a leakage current protective device (RCD⁄ FI)
with a measurement difference current of ≤ 30 mA.
The proper function of this fusing⁄protection must be checked at regular intervals.
The ambient temperature must not be higher than 50ºC.
It must be ensured that the product can be disconnected from the mains, e.g. via a
an all-pin switch as per EN 60335-1, sect. 24.3
T R A N S F O R M E R
The voltage supply from the 6 V DC SELV must only be fed via the included
transformer type 19769620. The transformer must be installed safe from outside
contact outside the zones 0, 1 and 2 in a socket in the wall to be provided by the
customer. (see page 47)
The mains voltage of 100 - 240 V AC 50 - 60 Hz must be supplied via a shutoff
device (switch) as well as a ground fault protector (RCD ⁄ FI) with a measured
differential current of ≤ 30 mA.
The transformer type 19769620 is only suited for the voltage supply of the
products 39117000 / 39118000.
Up to four fittings can be connected to a transformer on a ready-to-use set
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards. Installation to EN 1717
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ Any work may only be carried out in a de-energized state.
⁄ First, the basic set order no. 16180180 must be installed.
⁄ Pull the connecting cable between fitting ⁄ transformer into the empty conduit by
means of a cable retractor (EN 20)
⁄ All components must remain accessible.
⁄ After the installation, the output temperature of the fitting must be tested and set to
the temperate desired by the customer.
A D J U S T M E N T
This mixer has the following feature: background fade-out with integrated range
adjustment, that means the mixer is automatically adjusted on to the local conditions
(washbasin, brightness, reflection) by the sensory mechanism.
N O R M A L O P E R A T I O N
⁄ The range of the detection area or the removal of the switch-on⁄off point from the
fittings depends on the ambient optical conditions (for example, the shape and
reflection of the washstand and the ambient light) as well as on the shape, the size,
the speed and the reflection of the object that was brought into the detection area.
⁄ The detection area of the fittings or the distance of the switch-on⁄off point from the
fittings is approx. 40 to 180 mm in normal operation.
⁄ The detection of dark (for example grey-black) objects by the fittings is inadequate
because of their low reflection. The range of the detection area or the distance of
the switch-on⁄off point can be smaller than 40 mm.
⁄ The detection of bright or reflecting objects by the fittings is very good as a result of
their high reflectivity. The range of the detection area or the distance of the switch-
on⁄off point can be greater than 180 mm.
⁄ Strong light sources should not shine directly on the sensor window of the fittings.
⁄ Drops of water or condensed water on the sensor window of the fittings can initiate
unintended running of the water.
R A N G E S E T T I N G F O R I N F R A R E D P R O X I M I T Y E L E C T R O N -
I C S
EN
⁄ It may be necessary to maximize the range of the infrared proximity electronics by
manual mode switching when the fittings are connected to large washstands.
⁄ It is possible to select 5 different ranges. (Maximum range = Factory preset)
⁄ To change the range, carry out the following steps:
⁄ Interrupt the power supply for approx. 10 s (disconnect the electric plug-and-socket
connection between control module and outlet and reconnect after 10 s)
⁄ The blinking of the LED (see page 63 Fig. A) indicates the software version (e.g. 1 x
blinking = software version 1)
⁄ After a short break, the blinking of the LED indicates the currently set range (e.g. 3 x
blinking = range 3)
⁄ From here you have 50 s to set the range with the push of a button (see page 63
Fig. B) (with every new push of the button, the 50 s are started afresh); one push
of the button reduces the range respectively by one level (start is at level 5 =
maximum range, the next level is 4, down to level 1 = minimum range); the level is
indicated by the blinking of the LED after the push of the button; it is only possible
to switch to the next level after the status display LED has gone out. Once level 1 is
reached, the setting jumps back to level 5, etc. Calibration starts immediately after
the push of the button (approx. 10 s). If the button is pushed again, calibration is
interrupted and restarted. The remaining time for calibration is indicated by a per-
manent LED signal after the level display; subsequent to calibration, the range can
be tested and reset within 50 s by the push of a button etc.; after 50 s, the button is
locked for the range adjustment
T E C H N I C A L D A T A
This mixer series-produced with EcoSmart
®
(flow limiter)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 65°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C ⁄ 4 min
Follow-up time
1 - 2 s
Automatic switching-off
after 1 min
The product is exclusively designed for drinking water!
T R A N S F O R M E R
Input (IN)
100 – 240 V ⁄ 50 – 60 Hz 70 – 170 mA
Output (OUT)
6 V DC ⁄ 500 mA
Protection category
IP X1
Serial number
19769620 (see typeplate)
Dimensions
(see page 47)
weight
81 g
The transformer must not be installed in protection zones 0, 1 or 2.
The transformer must be installed safe from out side contact in a flush-mounted outlet
socket to be provided by the customer. This flush-mounted outlet socket is connected to
the fitting via an empty conduit EN 20.
Содержание Axor Citterio 39118 Series
Страница 46: ...AXOR Citterio 39117000 AXOR Citterio 39118XXX 55 50 140 2 2 0 140 2 2 0 4 6 EcoSmart EcoSmart 1 2 ...
Страница 48: ...SW 17 mm SW 24 mm SW 4 mm 90 90 1 2 3 4 8 ...
Страница 49: ...SW 5 mm 90 SW 4 mm SW 4 mm 90 90 4 5 6 7 4 9 ...
Страница 50: ...SW 5 mm 8 Nm SW 4 mm SW 4 mm 90 90 8 9 10 5 0 ...
Страница 51: ...SW 24 mm 1 mm 1 mm SW 3 mm 11 12 13 14 15 16 5 1 ...
Страница 52: ...12 30 M4x30 30 40 M4x45 SW 3 mm 4 Nm SW 3 mm 17 18 19 20 21 5 2 1 2 ...
Страница 53: ...SW 3 mm 6 Nm SW 3 mm 4 Nm 6 V 240 V 1 2 3 22 23 24 25 26 27 5 3 ...
Страница 54: ...SW 5 mm SW 4 mm 5 Nm 28 29 30 31 32 33 5 4 2 1 ...
Страница 55: ...90 SW 4 mm 90 34 35 36 37 5 5 ...
Страница 56: ... 0 1 Nm SW 3 mm 30 s X X 11 1 2 mm 1 2 38 39 40 41 42 5 6 ...
Страница 57: ... 10 s 10 20 mm 60 s 2 1 3 5 7 ...
Страница 58: ...SW 4 mm SW 4 mm 90 90 1 3 2 4 5 5 8 ...
Страница 60: ...SW 4 mm 90 90 12 A 11 13 B 6 0 ...
Страница 61: ...SW 3 mm SW 3 mm 6 Nm C E G D F H 2 1 6 1 ...