10
Attention!
The fitting must be installed, flushed and tested
after the valid norms.
Operation
The mixer is actuated by lifting the lever head.
Move to the left = hot water,
move to the right = cold water.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0.1 - 0.5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
max. 80° C
Recommended hot water temp.:
65° C
Rate of flow by 0.3 MPa:
approx. 32 l/min
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0.15 MPa.
To adjust the hot water limiter on single lever mixers, please
see page 36.
No adjustment is necessary when using a continuous flow
water heater.
English
Spare parts
(see page 3)
handle Starck
10492000
handle Carlton
17092XXX
handle Terrano
37491XXX
handle Allegroh
36093000
handle Steel
35093800
handle Massaud
18492000
face plate
96452XXX
face plate Massaud
98678000
flange
95010XXX
flange Terrano
96348XXX
flange Massaud
98684000
nut
95007000
locking screw for handle
96059000
seal
95008000
o-ring 13x2
98128000
noise reduction
94073000
cartridge cpl.
92730000
sub plate
96447000
fixing screw
96454000
extension 25 mm
13595000
extension 22 mm
13596XXX
screw cover
96338000
screw cover
96347000
screw cover
96681000
screw (4)
96525000
O-ring 48x5
98174000
XXX
= Colors
000 chrome plated
090 chrome plated/gold plated
120 chrome plated/porcelain colour
800 steel
810 satinox
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective, sedimentation
- Exchange cartridge
Hot water temperature too low, no
cold water.
Instantaneous water heater starts up
when cold water is selected.
- Hot water limiter incorrectly set
- Crossflow
- Set hot water limiter
- Exchange seal (13)