background image

10

ACCESSO

ri

ES

MAN9810312 08/21

RECOMMENDATIONS FOR USERS

Before using this product, make sure it is entirely suitable for your specific application and for the environment in which it is 

used. Any variation introduced by the user to the supplied equipment may degrade the tester’s performance. For your and the 

tester’s safety do not use or store it in hazardous environments.

WARRANTY

HI9810312

 is warranted for a period of one year against defects in workmanship and materials when used for its intended 

purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due 

to accidents, misuse, tampering, or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna 

Instruments office. If under warranty, report the model number, date of purchase, serial number, and the nature of the problem. 

If the repair is not covered by the warranty, you will be notified of the charges incurred. If the tester is to be returned to Hanna 

Instruments, first obtain a Returned Goods Authorization (RGA) number from the Technical Service department and then send it 

with shipping costs prepaid. When shipping any product, make sure it is shipped back in compliance with shipping regulations, 

thoroughly cleaned and free of any chemicals, and is properly packaged for complete protection.

13.  ACCESSORIES

Ordering Information Product Description

pH Buffer Solution

HI50016-02

pH 1.68 buffer solution, 20 mL sachet (25 pcs.)

HI70004P

pH 4.01 buffer solution, 20 mL sachet (25 pcs.)

HI70006P

pH 6.86 buffer solution, 20 mL sachet (25 pcs.)

HI70007P

pH 7.01 buffer solution, 20 mL sachet (25 pcs.)

HI70009P

pH 9.18 buffer solution, 20 mL sachet (25 pcs.)

HI70010P

pH 10.01 buffer solution, 20 mL sachet (25 pcs.)

HI77400P

pH 4.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each)

HI770710P

pH 10.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each)

Electrode Cleaning Solution

HI700601P

Electrode cleaning solution for general use, 20 mL sachet (25 pcs.)

HI7073L

Protein cleaning solution, 500 mL

HI7074L

Inorganic cleaning solution, 500 mL

HI7077L

Oil & Fat cleaning solution, 500 mL

Electrode Storage Solution

HI70300L

Electrode storage solution, 500 mL

HI70300M

Electrode storage solution, 230 mL

HI70300S

Electrode storage solution, 30 mL dropper

HI9072

Electrode storage solution, 13 mL dropper

Содержание HALO 2

Страница 1: ...INSTRUCTION MANUAL Foodcare Wireless pH Tester for Beer with built in specialized electrode HI9810312...

Страница 2: ...a Hanna Instruments product Please read this instruction manual carefully before using this instrument This manual will provide you with the necessary information for correct use of this instrument a...

Страница 3: ...ffer Set 6 pH Resolution 6 Bluetooth Wireless Mode 6 Bluetooth Pairing 7 Date Time 7 7 Bluetooth 7 8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation Guidelines 7 Procedure 7 St...

Страница 4: ...ution pH 0 01 or 0 1 pH mV 0 1 or 1 mV Temperature 0 1 C 0 1 F Accuracy pH 0 05 pH Temperature 0 5 C 0 9 F Calibration Up to three points or four points Automatic buffer recognition with Standard buff...

Страница 5: ...g against interferences from electrical noise or humidity The flat glass tip allows for direct pH measurement and prevents mash and cooled wort solids from collecting on the surface The extractable cl...

Страница 6: ...d battery type Dispose of old battery in accordance with local regulations 6 SETUP The Setup button is located inside the battery compartment After Setup configuration replace the cover Setup Menu Nav...

Страница 7: ...en the tester is in discoverable mode it will appear in the list of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the...

Страница 8: ...e in the second buffer rinse beaker then in the second calibration buffer Wait until the measurement is stored and the stability indicator disappears 7 After the second point has been stored CAL SAVE...

Страница 9: ...should be kept hydrated When not in use add a few drops of storage solution to the storage cap If storage solution is not available pH 4 01 or pH 7 01 buffer can be used Note Do not store the electrod...

Страница 10: ...RGA number from the Technical Service department and then send it with shipping costs prepaid When shipping any product make sure it is shipped back in compliance with shipping regulations thoroughly...

Страница 11: ...vide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not insta...

Страница 12: ...World Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN9810312 Printed in ROMANIA...

Отзывы: