PRELIMINARY EXAMINATION
GENERAL DESCRIPTION
LP2000-11
is housed in a rugged and lightweight case, with an
easy-to-read LCD.
The meter is simply to use. All operations can be carried out with only
five keys and troubleshooting functions can be performed with
displayed error code guides. A positive-locking system guarantees that
the cuvet is firmly placed in the cell. The keypad is water-resistant
and can be wiped with a moist cloth for quick cleanups.
Two or three points calibration (0, 10, 500 FTU*) can be easily
performed using available standards.
Remove the instrument from the packing material and examine it to make
sure that no damage has occurred during shipping. If there is any
damage, notify your Dealer.
LP2000-11
is supplied with:
•
Glass cuvet with cap
• AMCO-EPA-1 turbidity calibration solutions (
HI 93703-0
@0 FTU
and
HI 93703-10
@10 FTU), 30 mL each
•
12 Vdc power adapter and instruction manual
Note:
Save all packing material until you are sure that the instrument
functions correctly. Any defective item must be returned in its
original packaging with the supplied accessories.
LP2000-11
turbidity meter is a bench top, microprocessor-based instrument
used to determine the turbidity of water and wastewater. The meter covers
a 0-1000 FTU range in two scales: 0.00 to 50.00 FTU and 50 to 1000
FTU. The autoranging feature sets the appropriate range for the
measurement.
The serial interface is supported connecting any available serial port on
your PC and a 5-pin socket on the meter.
Note:
LP2000-11
has been designed according to the ISO 7027
International Standard, consequently the turbidity
measurement units are expressed in FTU (Formazine Turbidity
Unit). FTU is identical to the other internationally recognized
unit NTU (Nephelometric Turbidity Unit).
Dear Customer,
Thank you for choosing a Hanna Product. Please read this instruction
manual carefully before using the instrument. It will provide you with
the necessary information for the correct use of the instrument, as well
as a precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at
.
These instruments are in compliance with the
directives.
TABLE OF CONTENTS
Preliminary Examination ............................................................. 3
General Description ..................................................................... 3
Principle of Operation ................................................................. 4
Specifications .............................................................................. 5
Functional Description ................................................................. 6
Operational Guide ...................................................................... 7
Power Connection ........................................................ 7
Measurement Procedure ...................................................... 7
Storing samples in memory ................................................ 10
Clearing Logged Data ........................................................ 10
Viewing Logged Data ........................................................ 11
Date and Time setup ......................................................... 11
Error Codes ....................................................................... 12
Ensure Accurate Measurements ........................................... 13
Sources of Interference ....................................................... 14
Calibration ............................................................................... 14
Calibration Procedure ........................................................ 14
Viewing Calibration Date ................................................... 16
Ensure Accurate Calibration ................................................ 17
Standard Suspension ........................................................ 17
RS 232 Connection ................................................................... 18
Accessories ................................................................................ 18
Warranty ................................................................................. 19
* 1 FTU = 1 NTU