Preliminary Examination

Remove the tester and accessories from the packing material and 
examine it carefully. If you require any further information, please contact 
Hanna Instruments technical support team at [email protected].
Each 

HI98120

 is delivered in a cardboard box and is supplied with:

• 

HI70022 

ORP test solution, 470 mV, 20 mL sachet (6 pcs.)

• 

HI73120

 ORP electrode

• 

HI73128

 Electrode removal tool

• 1.5V batteries (4 pcs.)
• Instrument quality certificate
• Instruction manual

Note: 

Save all packing material until you are sure that the tester 

works correctly. Any damaged or defective item must be returned 

in its original packing material with the supplied accessories.

General Description & Intended Use

HI98120

 is a compact ORP and temperature tester. It features a 

two-buttons operation system and is easy to use. The compact and 
waterproof casing is designed to float if accidentally dropped in the 
water. The tester is factory calibrated and measures temperature in 
both °C and °F. It displays a stability tag that will disappear once the 
reading has stabilized.
Battery level and low-battery indicator are clearly displayed on 
the LCD to alert the user in the event that low battery power could 
adversely affect the readings.

BEPS (Battery Error Prevention System)

The tester will automatically shut off if there is not enough power to 
get an accurate reading.

ORP Probe

HI98120

 is supplied together with 

HI73120

 ORP replaceable 

electrode. 

Temperature Sensor

The stainless steel temperature sensor facilitates faster and more 
accurate temperature measurement.

Specifications

Range

±1000 mV
-5.0 to 60 °C / 23.0 to 140.0 °F

Resolution

1 mV
0.1 °C / 0.1 °F

Accuracy 
(@25 °C/77 °F)

±2 mV
±0.5 °C / ±1.0 °F

Calibration

Factory calibrated

Electrode

HI73120

 ORP electrode (included)

Battery type

1.5 V (4 pcs.)

Battery life

Approx. 300 hours of use

Auto-off

After 8 minutes

Environment

-5 to 50 °C (23 to 122 °F); RH 100%

Dimensions

171 x 41 x 26 mm (6.7 x 1.6 x 1.0“) 

Weight

83 g (2.9 oz.)

Functional Description

Liquid Crystal 

Display
SET/HOLD 

button

Battery 

compartment

/MODE 

button

Temperature 

sensor

HI73120 

ORP electrode

LCD Display

1.  Stability tag
2.  Battery life percentage indicator
3.  Low battery indicator
4.  Measurement unit
5.  First LCD line
6.  Second LCD line

Operational Guide

Turning the Tester ON / OFF 

Press and hold  /MODE. Al LCD segments will be displayed for a 
few second followed by battery life percentage indicator (e.g. % 100 
BATT).

To turn the tester OFF, from measurement mode, press MODE. “OFF” 
will be displayed on the second LCD line and the tester will turn off.

HOLD Mode

From measurement mode, press and hold SET/HOLD until HOLD is 
displayed. mV reading will be frozen on the LCD. Press either buttons 
to resume measurement mode.

Setup

Setup mode allows the selection of temperature unit.
To enter the Setup mode, press  /MODE until “TEMP“ and the 
current temperature unit are displayed on the second LCD line (e.g. 
“TEMP °C”).
Use SET/HOLD to change the temperature unit, and press  /MODE to 
return to measurement mode. 

Measurement

Place the electrode in the solution to be tested while stirring it gently. 
The measurement should be taken after the stability tag ( ) has 
disappeared.

The ORP (mV) value is displayed on the first LCD line and the 
temperature on the second LCD line.

Note: 

If measurements are taken successively, rinse the probe 

thoroughly in distilled or deionized water to eliminate cross-

contamination. After cleaning, rinse the probe with some of the 

sample to be measured.

Maintenance

Please read the information below to ensure the highest possible 

accuracy.
• If measurements are taken successively, rinse the probe

thoroughly in distilled or deionized water to eliminate cross-

contamination.

• Clean the electrode monthly using by keeping the electrode in

HI7061

 General purpose cleaning solution for 30 minutes and

rinsing the probe thoroughly with water.

• When not in use, add a few drops of 

HI70300

 Storage solution to 

the protective cap. Never store the probe in distilled or deionized 

water.