Hanna Instruments HI97712 Скачать руководство пользователя страница 3

3

TABLE OF CONTENTS

TABLE OF CONTENTS

1.  PRELIMINARY EXAMINATION ..........................................................................4
2.  SAFETY MEASURES ........................................................................................5
3. ABBREVIATIONS  ...........................................................................................5
4. SPECIFICATIONS ............................................................................................6
5. DESCRIPTION ................................................................................................7

5.1.  GENERAL DESCRIPTION & INTENDED USE ..............................................7
5.2.  FUNCTIONAL DESCRIPTION ...................................................................8
5.3.  PRECISION & ACCURACY .......................................................................9
5.4.  PRINCIPLE OF OPERATION ....................................................................9
5.5.  OPTICAL SYSTEM ................................................................................10

6.  GENERAL OPERATIONS .................................................................................11

6.1.  METER VALIDATION: CAL CHECK & CALIBRATION ...................................11
6.2.  CHEMICAL FORMULA & UNIT CONVERSION ..........................................12
6.3. GLP ...................................................................................................13
6.4.  LOGGING DATA & LOG RECALL .............................................................13
6.5.  GENERAL SETUP ................................................................................14
6.6.  REAGENTS & ACCESSORIES .................................................................16
6.7.  CONTEXTUAL HELP .............................................................................16
6.8.  BATTERY MANAGEMENT .....................................................................17

7. PHOTOMETER ..............................................................................................18

7.1.  PROPER USE OF POWDER PACKET .......................................................18
7.2.  CUVETTE PREPARATION ......................................................................18

8.  METHOD PROCEDURE ..................................................................................20
9.  WARNING & ERROR DESCRIPTIONS...............................................................24
10.  BATTERY REPLACEMENT .............................................................................26
11. ACCESSORIES ............................................................................................27

11.1.  REAGENT SETS.................................................................................27
11.2.  OTHER ACCESSORIES .......................................................................27

CERTIFICATION .................................................................................................28
RECOMMENDATIONS FOR USERS .......................................................................28
WARRANTY ......................................................................................................29

Содержание HI97712

Страница 1: ...INSTRUCTION MANUAL HI97712 Aluminum Photometer...

Страница 2: ...a Hanna Instruments product Pleasereadthisinstructionmanualcarefullybeforeusingthisinstrument This manual will provide you with the necessary information for correct use of this instrument as well as...

Страница 3: ...6 1 METER VALIDATION CAL CHECK CALIBRATION 11 6 2 CHEMICAL FORMULA UNIT CONVERSION 12 6 3 GLP 13 6 4 LOGGING DATA LOG RECALL 13 6 5 GENERAL SETUP 14 6 6 REAGENTS ACCESSORIES 16 6 7 CONTEXTUAL HELP 16...

Страница 4: ...Cuvette A HI97712B CAL Check Cuvette B for Aluminum Cloth for wiping cuvettes Scissors 1 5V AA Alkaline batteries CAL Check standard certificate Instrument quality certificate Instruction manual Each...

Страница 5: ...urs wipe up immediately and rinse with plenty of water If reagent contacts skin rinse the affected area thoroughly with water Avoid breathing released vapors Waste disposal For proper disposal of reag...

Страница 6: ...etector Silicon photocell Cuvette type Round 24 6 mm diameter 22 mm inside Additional Specifications Auto logging 50 readings Display 128 x 64 pixel B W LCD with backlight Auto off After 15 minutes of...

Страница 7: ...mance of the instrument at any time and apply a user calibration if necessary Hanna Instruments CAL Check cuvettes are made with NIST traceable standards The built in tutorial mode guides users step b...

Страница 8: ...ver Keypad Description The keypad contains 3 direct keys and 3 functional keys with the following functions Press the functional key to perform the function displayed above it on the LCD Press and hol...

Страница 9: ...sorbed by atoms molecules or crystal lattices Photometric chemical analysis is based on specific chemical reactions between a sample and reagent to produce a light absorbing compound If pure absorptio...

Страница 10: ...luminous efficiency providing more light while using less power They also produce little heat which could otherwise affect electronic stability LEDs are available in a wide array of wavelengths wherea...

Страница 11: ...m direct sunlight by keeping them in the original packing Store between 5 and 30 C 41 to 86 F do not freeze To perform a CAL Check 1 Press CAL Check from measurement mode The Not Available message or...

Страница 12: ...creen OUT OF SPECIFICATION A user calibration is not allowed the measured value is outside of the tolerance window Check the certified value expiration date and clean the outside of the cuvette Repeat...

Страница 13: ...l measurements Every time a measurement is made the data is automatically saved The data log can hold 50 individual measurements When the data log is full 50 data points the meter will rewrite the old...

Страница 14: ...ease or decrease the value Press Accept to confirm or the key to return to the Setup menu without saving the new value Contrast Option 0 to 100 Press Modify to change the display s contrast Use the fu...

Страница 15: ...ption Comma or Period Press the functional key to select the desired decimal separator The decimal separator is used on the measurement screen Language Press Modify to change the language Use the func...

Страница 16: ...ore Factory Settings Press Select to reset to factory settings Press Accept to confirm or Cancel to exit without restoring the factory settings 6 6 REAGENTS ACCESSORIES Press the key to enter the menu...

Страница 17: ...o diagnostic test when it is powered on During this test the Hanna Instruments logo will appear on the LCD If the auto diagnostic test was successful the meter is ready for use The battery icon on the...

Страница 18: ...hnique is listed in the method procedure The mixing method is indicated with shake gently using one of the following icons In order to avoid reagent leaking and to obtain more accurate measurements cl...

Страница 19: ...in the method It is possible to take multiple readings in a row but it is recommended to take a new zero reading for each sample and to use the same cuvette for zeroing and measurement when possible D...

Страница 20: ...ee ACCESSORIES section MEASUREMENT PROCEDURE Note If tutorial mode is disabled follow the measurement procedure below If the tutorial mode is enabled press Measure and follow the messages on the scree...

Страница 21: ...he cap is positioned securely in the groove Press Zero The display will show a 15 minute countdown prior to zeroing the blank To skip the timer press Zero twice The display will show 0 0 when the mete...

Страница 22: ...O3 INTERFERENCES Interference may be caused by Alkalinity above 1000 mg L Phosphate above 50 mg L Iron above 20 mg L Fluoride must be absent If the fluoride concentration is known the aluminum concent...

Страница 23: ...mple 4 From the intersection of the fluoride and aluminum line follow the line to the left until it intersects the y axis This point corresponds to the corrected aluminum concentration in the sample E...

Страница 24: ...the zero cuvettes are inverted Swap the cuvettes and repeat the measurement There is either too much light or the instrument can not adjust the light level Please check the preparation of the zero cu...

Страница 25: ...e meter If the issue persists please contact Hanna Instruments technical support Battery level is too low for the meter to function properly Replace the batteries with new ones Tutorial mode has been...

Страница 26: ...batteries follow these steps Turn the instrument off by pressing and holding the key Remove the battery cover by turning it counterclockwise Remove the old batteries replace them with three new 1 5V...

Страница 27: ...de Description HI7101412 blue carrying case for HI977xx and 2 CAL Check cuvettes HI731318 cloth for wiping cuvettes 4 pcs HI731331 glass cuvette 4 pcs HI731336N cap for glass cuvette 4 pcs HI93703 50...

Страница 28: ...ste Hand them over to the appropriate collection point for recycling Ensuring proper product and battery disposal prevents potential negative consequences fortheenvironmentandhumanhealth Formoreinform...

Страница 29: ...equired contact your local Hanna Instruments Office If under warranty report the model number date of purchase serial number engraved on the bottom of the meter and the nature of the problem If the re...

Страница 30: ...30 MAN97712 11 19...

Страница 31: ...Hanna Instruments reserves the right to modify the design construction or appearance of its products without advance notice...

Страница 32: ...World Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN97712 Printed in ROMANIA...