Preliminary Examination

1.  PRELIMINARY EXAMINATION

Remove the instrument and accessories from the packaging and examine it carefully. For further assistance, 
please contact your local Hanna Instruments

®

 office or email us at [email protected].

Each 

HI97105

 or 

HI97115 

is supplied with:

•  Sample cuvette (2 pcs.)

•  Sample cuvette cap (2 pcs.)

•  1.5V AA Alkaline batteries (3 pcs.)

•  Instrument quality certificate
•  Quick reference guide with instructions for manual download

Each 

HI97115

C

* is delivered in a rugged carrying case and is supplied ** with:

•  Sample cuvette (2 pcs.)

•  Sample cuvette cap (2 pcs.)

•  Marine pH reagent, 30 mL dropper (1 pc.)

•  Marine Alkalinity reagent, 30 mL bottle (1 pc.)

•  Marine Ammonia starter kit 

Reagent A, 30 mL bottle (1 pc.)

Reagent B and C (reagent for 25 tests, each)

•  Marine Calcium starter kit 

Reagent A, 30 mL bottle (1 pc.)

Reagent B (reagent for 25 tests)

•  Marine Magnesium starter kit

Reagent A, 120 mL bottle (1 pc.)

Magnesium Indicator reagent (for 25 tests)

•  Marine Nitrate High Range reagent (for 25 tests)

•  Marine Nitrite Ultra Low Range reagent (for 25 tests)

•  Marine Phosphate Ultra Low Range reagent (for 25 tests)

•  1 mL graduated syringe with tip (3 pcs.)

•  Minipipette with tip (1 pc.)

•  3 mL Pasteur pipette (2 pcs.)

•  5 mL syringe with black printing and tip (1 pc.)

•  5 mL syringe with blue printing and tip (1 pc.)

•  1.5V AA Alkaline batteries (3 pcs.)

•  Cloth for wiping cuvettes

•  Scissors

•  Instrument quality certificate

•  Quick reference guide with instructions for manual download

Note

: Save all packing material until you are sure that the instrument works correctly. Any damaged or defective 

item must be returned in its original packing material with the supplied accessories.

*    

HI97115U

C

, instrument code in the USA.

**   Marine Nitrate Low Range testing reagent not supplied.

Содержание HI97105

Страница 1: ...ive Woonsocket RI 02895 USA www hannainst com HI97105 HI97115 X pH X Alkalinity X Ammonia X Calcium X Magnesium X Nitrate Low Range X Nitrate High Range X Nitrite Ultra Low Range X Phosphate Ultra Low...

Страница 2: ...on Selection 17 6 3 Collecting Measuring Samples and Reagents 18 6 4 Cuvette Preparation 18 6 5 Measurement Recommendations 19 6 6 Battery Management 20 7 Method Procedure 21 7 1 Marine pH 21 7 2 Mari...

Страница 3: ...Calcium starter kit Reagent A 30 mL bottle 1 pc Reagent B reagent for 25 tests Marine Magnesium starter kit Reagent A 120 mL bottle 1 pc Magnesium Indicator reagent for 25 tests Marine Nitrate High Ra...

Страница 4: ...oper disposal of reagent kits and reacted samples 3 SPECIFICATIONS 3 1 PHOTOMETER SPECIFICATIONS Auto logging 200 readings Display 128 x 64 pixel B W LCD with backlight Auto off After 15 minutes of in...

Страница 5: ...orimetric EDTA Method using calmagite indicator Reaction between magnesium and the reagents causes a blue to violet tint in the sample Nitrate LR 0 00 to 5 00 ppm as NO3 0 01 ppm 0 25 ppm 2 of reading...

Страница 6: ...der in the same position every time With the CAL Check functionality users are able to validate the performance of the instrument at any time Hanna Instruments CAL Check cuvettes are certified against...

Страница 7: ...in Romania Woonsocket RI USA 3 x 1 5V AA SN XXXXXXXXXXXX 1 Liquid Crystal Display LCD 2 Keypad 3 ON OFF power button 4 Cuvette holder 5 Indexing mark 6 Battery cover Keypad Description The keypad con...

Страница 8: ...tal lattices Photometric chemical analysis is based on specific chemical reactions between a sample and reagent to produce a light absorbing compound If pure absorption occurs the fraction of light ab...

Страница 9: ...ions and scratches reducing the need to index the cuvette 5 GENERAL OPERATIONS 5 1 METER VALIDATION CAL CHECK Validation of the photometer involves verifying the concentration of the certified CAL Che...

Страница 10: ...100 610 for Alkalinity Ammonia Calcium Magnesium Phosphate ULR then press Next to continue The Please wait message will be displayed during the measurement Note HI97100 ZERO HI97100 525 and HI97100 61...

Страница 11: ...ument features a data autolog function to help users keep track of all measurements Every time a measurement is made the data is automatically saved The data log can hold 200 individual measurements N...

Страница 12: ...unctional keys to increase or decrease the percentage intensity value Press Accept to confirm or the key to return to the Setup menu without saving the new value Contrast Option 0 to 100 Press Modify...

Страница 13: ...n Language Press Modify to change the language Use the functional keys to select the desired language Press Accept to choose one of the languages installed Beeper Option Enable Disable When enabled a...

Страница 14: ...isplayed in the top right corner of the screen Meter ID Press Modify and use the functional keys to set desired ID Press Accept to confirm or the key to return to the Setup menu without saving the new...

Страница 15: ...y to enter the menu Use the functional keys to select Instruction manual and press Select see details on how to access the online manual Scan the QR code or use link to download the PDF Press the key...

Страница 16: ...gured in Setup a 6 digit Bluetooth pin will be generated the first time the instrument and the smart device are paired Once the devices are paired the pin is not required when reconnected Deleting Pai...

Страница 17: ...ed method 6 2 READING LOCATION SELECTION The user has the option to select a measurement location from up to 25 TANKS HI97105 and from up to 100 TANKS HI97115 From menu having previously selected requ...

Страница 18: ...a vertical position above the cuvette and then push the plunger down into the syringe to deliver desired volume into the cuvette Proper Use of Minipipette 1 Attach the pipette tip 2 Press the button...

Страница 19: ...cleaning cloth or a lint free wipe prior to insertion Shaking the cuvette can generate bubbles in the sample causing higher readings To obtain accurate measurements remove such bubbles by swirling or...

Страница 20: ...right Always use clean dry cuvettes and syringes tips Rinse with deionized RODI water only never rinse with tank water Dry the cuvettes before use to prevent dilution Clean the syringes and tips befo...

Страница 21: ...ollow the messages on the screen Fill the cuvette with 10 mL of unreacted sample up to the mark Replace the plastic stopper and the cap Insert the cuvette into the holder and ensure that the notch on...

Страница 22: ...L of unreacted sample up to the mark Replace the plastic stopper and the cap Insert the cuvette into the holder and ensure that the notch on the cap is positioned securely in the groove Press Zero The...

Страница 23: ...ent into a clean dry cuvette Caution HI784A 0 is corrosive Dispense liquid slowly and avoid contact with skin and eyes Using scissors open one packet of HI784B 0 Reagent B along the dotted line Push t...

Страница 24: ...ow a 15 minute countdown prior to the measurement To skip the timer press Read When the timer ends the meter will perform the reading The instrument displays the ammonia ammonium concentration in ppm...

Страница 25: ...arine method using the procedure described in Method Selection section Note If tutorial mode is disabled follow the measurement procedure below If the tutorial mode is enabled press Measure and follow...

Страница 26: ...t of HI7582 Marine Calcium Reagent B Replace the plastic stopper and the cap and shake vigorously for 15 seconds or until the powder is completely dissolved Allow air bubbles to dissipate for 15 secon...

Страница 27: ...e O rings remain in the tip for a proper seal Use the 5 mL syringe with black printing to measure 4 mL of HI783A 0 reagent Ensure there is no excess reagent on the syringe tip then slowly dispense the...

Страница 28: ...meter will perform the reading The instrument displays ppm of Mg 2 Rinse cuvettes caps syringes and tips thoroughly with deionized RODI water and allow to dry completely before storing INTERFERENCES...

Страница 29: ...use excessive force Dilution 1 Measure 1 mL of sample using HI740143 1 mL graduated syringe 2 Dispense into mixing vial 3 Add nitrate nitrite free artificial seawater up to the 10 mL mark using HI7401...

Страница 30: ...vette has been filled up to the 10 mL mark Replace the plastic stopper and the cap Insert the cuvette into the holder and ensure that the notch on the cap is positioned securely in the groove Press Ze...

Страница 31: ...e the plastic stopper and the cap Insert the cuvette into the holder and ensure that the notch on the cap is positioned securely in the groove Press Zero The display will show 0 0 when the meter is ze...

Страница 32: ...e up to the mark Replace the plastic stopper and cap Insert the cuvette into the holder and ensure that the notch on the cap is positioned securely in the groove Press Zero The display will show 0 0 w...

Страница 33: ...tion section Note If tutorial mode is disabled follow the measurement procedure below If the tutorial mode is enabled press Measure and follow the messages on the screen Fill the cuvette with 10 mL of...

Страница 34: ...instrument displays the results in ppm of phosphate PO4 3 Press the key and use the functional keys to select Chemical Form Use the functional keys and press Select to change displayed chemical formul...

Страница 35: ...adjust the light level Please check the preparation of the zero cuvette and that the sample does not contain any debris The meter is overheating It cannot operate within published accuracy specificat...

Страница 36: ...the oldest Displays before a new log would overwrite the oldest record Press Continue to accept A critical error has occurred Restart the meter If the issue persists please contact Hanna Instruments t...

Страница 37: ...6M Deionized water 230 mL HI7101419 Blue carrying case for HI97115C HI97115UC HI731318 Cloth for wiping cuvettes 4 pcs HI731331 Glass cuvette 4 pcs HI731336N Cap for glass cuvette 4 pcs HI731360 Glass...

Страница 38: ...city your local household waste disposal service or the place of purchase RECOMMENDATIONS FOR USERS Before using this product make sure it is entirely suitable for your specific application and for th...

Страница 39: ...mful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users are required to correct the interference at thei...

Страница 40: ...Zealand ACMA ANNA B1 complies with AS NZS 4268 2012 standard Japan MIC 5 The module complies with the Japanese Technical Regulation Conformity Certification of Specified Radio Equipment ordinance of...

Отзывы: