Hanna Instruments HI6221 Скачать руководство пользователя страница 2

Hanna Instruments Inc., 584 Park East Drive, Woonsocket, RI 02895  USA

 

www.hannainst.com

Please retain for future use. 

QR6221 02/23

All Hanna instruments conform to the CE European Directives and UK Standards, and our production facilities are ISO 9001 certified. 

HI6221

 is warranted for a period 

of two years and the probes for six months against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. 

For technical information e-mail us at 

[email protected]

. Visit 

www.hannainst.com

 for more information about Hanna Instruments and our products.

Capacitive touchscreen

Channel  

Settings

Back key

Home key

Menu key

Users System

Settings

Measurement

Settings

Log Recall Help

•    return to a previous hierarchical menu level

•    access to measurement screen & configured profile

•    access to:

 

`

Users

 – login & rights configuration

 

`

System Settings

 – system configuration, connectivity & printing

 

`

Measurement Settings

 – measurement configuration

 

`

Log Recall

 – logged measurement data

 

`

Help

 – support

•    from measurement screen, tap to access measurement menu

Electrode usage guidelines & Calibration tips

• Remove protective cap and rinse with water to eliminate salt build up.

• Check correct electrolyte level. Refill when level falls below ½” 

from the fill hole opening. Keep the fill hole open (1) during 

calibration and measurement.

• To refresh the the electrode, soak in 

HI70300

 Storage solution 

for at least 30 minutes.

• Keep the glass bulb (3) and junction (2) hydrated to maintain a 

quick response time. 

Store with a few drops of storage solution in the protective cap.

• Keep the junction (2) immersed during calibration/measurement.

1

2

3

Calibration tips

• Ensure electrode connection to correct meter input.

• Rinse with the calibration solution intended for calibration next. 

Discard rinsing solution.

• Place electrode and temperature sensor in calibration solution.

Use a rinse beaker and a separate calibration beaker for each buffer.

• On first use, tap 

Clear Calibration 

to clear all buffers and start new.

pH measurement tips

• Only work with recently calibrated electrodes.

• Use the arm holder for electrode transfer in and out of containers.

• Rinse with purified water between samples.

• Pour two beakers of sample: use one to rinse the sensor and the 

second for measurement (limit contamination).

• Gently stir the sample to ensure a representative measurement.

• Keep the fill solution topped off to permit the fill solution flow 

through the ceramic junction and maintain a stable reference signal.

• Record measured data once the reading is stable.

Logging in & Creating a new account

1. Power the meter and tap 

.

2. Tap 

  followed by  .

3. Tap 

Edit Users

 to enter Account Management.

4. Tap   to enable Account Creation and Logins. Tap   to return.

5. Tap 

Logout

 to enter Users screen. Tap the plus symbol avatar.

6. Input user name and tap 

.

7. Enter password and tap 

. Re-enter password to confirm.

Отзывы: