Remove the instrument from the packing material and examine it
carefully to make sure that no damage has occurred during shipment.
If noticeable damage is found, notify your Dealer.
Each meter is supplied with:

• HI 1285 combination, amplified, double-junction, gel pH elec-

trode with incorporated EC/TDS probe and built-in
temperature sensor and 1m (3.3') cable

HI70007 pH 7.01 sachet (1 pc)

HI70031, 1413 µS/cm sachet (1 pc)

HI70032, 1382 ppm sachet (1 pc)

Instruction Manual

• 9 V battery.

Note:

 Save all packing material until you are sure that the instrument

functions correctly. Any defective items must be returned in the
original packing together with the supplied accessories.

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

GENERAL DESCRIPTION

HI 9810 

is the most complete and versatile portable pH/EC/TDS

meters ever manufactured. Designed with utmost precision and
simplicity, this meter provides 3 kinds of measurements. The pH, EC
and TDS ranges are easily selected using a membrane keyboard on
the front panel.
The conductivity of a solution depends on the temperature and for this
reason measurements are carried out with reference to a standard
temperature of 25 C. If the solution measured has a different tem-
perature than 25 C, compensation must be performed.

HI 9810 

automatically compensates for temperature changes with a

built-in temperature sensor and circuitry. The temperature coefficient
is fixed at 2%/ C.

HI 9810

 is designed for simplicity of use in taking pH, µS/cm and

mg/L measurements.

ISO 9000 Certified
Company since 1992

Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the meter.
This manual will provide you with the necessary information for a
correct use of the instrument, as well as a precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at [email protected].
These instruments are in compliance with 

 directives

EN 50081-1, EN 50082-1 and EN61010-1.

TABLE OF CONTENTS

TABLE OF CONTENTS

TABLE OF CONTENTS

TABLE OF CONTENTS

TABLE OF CONTENTS

PRELIMINARY EXAMINATION ..................................................... 3
GENERAL DESCRIPTION ............................................................. 3
FUNCTIONAL DESCRIPTION ....................................................... 4
SPECIFICATIONS ....................................................................... 5
OPERATIONAL GUIDE ................................................................ 6
pH CALIBRATION ..................................................................... 8
EC/TDS CALIBRATION ............................................................... 9
pH VALUES AT VARIOUS TEMPERATURES ................................. 10
TEMPERATURE COMPENSATION ............................................... 11
EC/TDS COVERSION FACTOR .................................................... 11
ELECTRODE CONDITIONING AND MAINTENANCE ......................... 12
ACCESSORIES ......................................................................... 14
BATTERY REPLACEMENT ........................................................... 16
OTHER PRODUCTS FROM HANNA ............................................ 17
WARRANTY ............................................................................ 18
CE DECLARATION OF CONFORMITY ........................................... 19

Содержание HI 9810

Страница 1: ...Instruction Manual HI 9810 Portable pH EC TDS Meter h t t p w w w h a n n a i n s t c o m This Instrument is in Compliance with the CE Directives...

Страница 2: ...rature and for this reason measurements are carried out with reference to a standard temperature of 25 C If the solution measured has a different tem perature than 25 C compensation must be performed...

Страница 3: ...with a of 2 C Electrode HI 1285 combination pH EC TDS electrode with temperature sensor and 1 m 3 3 cable included Battery Type 9 Volt 150 hours of continuous use Environment 0to50 C 32to122 F max 95...

Страница 4: ...N Each meter is supplied complete with a 9V battery Slide off the battery compartment cover on the back of the meter see page 16 install the battery while paying attention to its polarity Connect the...

Страница 5: ...chemicals d Where extreme accuracy is required PREPARATION Pour small quantities of pH 7 01 HI 7007 or HI 8007 orpH4 01 HI 7004orHI 8004 or pH 10 01 HI 7010 or HI 8010 solution into a clean beaker To...

Страница 6: ...gs are usually normalized at 25 C HI 9810 automatically compensates for temperature differences with a built in temperature sensor circuitry With this compensation the display shows the readings at 25...

Страница 7: ...e electrode and recalibrate the meter to see if the problem is alleviated ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING AND MAINTEN...

Страница 8: ...1 Rugged carrying case ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES pH CALIBRATION SOLUTIONS HI 70004P pH 4 01 Buffer Sachets 25 x 20 mL HI 7004M pH 4 01 Buffer Solution 230 mL HI 7004L...

Страница 9: ...EMICAL TEST KITS CHLORINE METERS CONDUCTIVITY TDS METERS DISSOLVED OXYGEN METERS HYGROMETERS ION SPECIFIC METERS Colorimeters MAGNETIC STIRRERS Na NaCl METERS pH ORP Na ELECTRODES PROBES DO S cm RH T...

Страница 10: ...warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions The electrodes and the probes are warranted for a per...

Страница 11: ...plications The reference literature currently covers areas such as Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry and many others New reference material is constantly b...

Отзывы: