TABLE OF CONTENTS

PRELIMINARY EXAMINATION

Remove the instrument from the packing materials and examine
carefully to ensure no damage has occurred during shipping. If
any damage has occurred, notify your Dealer or closest Hanna
Customer Service Center.
Each HI 96803 instrument is supplied with:

• 9 V battery
• Instruction manual

Note: Save all packing material until you are sure that the

instrument functions correctly. A defective instrument
must be returned in its original packing.

Dear Customer,
Thank you for choosing a Hanna Instruments product.
Please read this instruction manual carefully before using this instrument.
This manual will provide you with the necessary information for correct
use of this instrument, as well as a precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at [email protected] or view our worldwide contact list at
www.hannainst.com.

PRELIMINARY EXAMINATION .................................................... 2
GENERAL DESCRIPTION ............................................................ 3
SPECIFICATIONS ........................................................................ 3
PRINCIPLE OF OPERATION ....................................................... 4
FUNCTIONAL DESCRIPTION ....................................................... 5
DISPLAY ELEMENTS .................................................................. 6
MEASUREMENT GUIDELINES ..................................................... 6
CALIBRATION PROCEDURE ....................................................... 7
MEASUREMENT PROCEDURE ..................................................... 8
MAKING A STANDARD % GLUCOSE SOLUTION ......................... 9
TO CHANGE TEMPERATURE UNIT .............................................. 9
BATTERY REPLACEMENT ......................................................... 10
WARRANTY.............................................................................. 10
ERROR MESSAGES ................................................................... 11

Содержание HI 96803

Страница 1: ...1 Instruction Manual www hannainst com HI 96803 Refractometer for Glucose Measurements...

Страница 2: ...ctive instrument must be returned in its original packing Dear Customer Thank you for choosing a Hanna Instruments product Please read this instruction manual carefully before using this instrument Th...

Страница 3: ...rsand is easily portable for measurements on the go The measurement technique and temperature compensation employ methodologyrecommendedintheICUMSAMethodsBook Internationally recognizedbodyforSugarAna...

Страница 4: ...ve index thereisacriticalangleatwhichanincomingbeamoflightcannolonger refract but will instead be reflected off the interface The critical angle can be used to easily calculate the refractive index ac...

Страница 5: ...ry Compartment TOP VIEW BOTTOM FUNCTIONAL DESCRIPTION 1 Liquid Crystal Display LCD 2 Secondary Display 3 Primary Display 4 READ Key User Measurement 5 ZERO Key User Calibration 6 ON OFF 7 Stainless St...

Страница 6: ...pipettestotransferallsolutions Donotusemetallictools such as needles spoons or tweezers as these will scratch the prism Toreducetheeffectsofevaporationorabsorptionofwaterwhentaking readings over a per...

Страница 7: ...distilled or deionized water Make sure the prism is completely covered Note If the ZERO sample is subject to intense light such as sunlight or another strong source cover the sample well with your ha...

Страница 8: ...ately 1 minute to allow thermal equilibration 3 Press the READ key The result is displayed in units of by weight w w Note The last measurement value will be displayed until the next sample is measured...

Страница 9: ...n a water bath Remove solution when glucosehasdissolved Coolcompletelybeforeuse Example with 25 g Glucose g Water g Total 25 25 000 75 000 100 000 8seconds TO CHANGE TEMPERATURE UNIT To change the tem...

Страница 10: ...he charges incurred If the instrument is to be returned to Hanna Instruments first obtain a Returned Goods Authorization number from the Technical Service department and then send it with shipping cos...

Страница 11: ...a C N O t n e m g e s w o l C T A s d e e c x e e r u t a r e p m e T g n i r u d C 0 0 1 t i m i l n o i t a r b i l a c I H t y r a m i r p y a l p s i d l a C N O t n e m g e s h g i h C T A s d e...

Страница 12: ...na Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA Technical Support for Customers Tel 800 426 6287 Fax 401 765 7575 E mail tech hannainst com www hannainst com Lo...