Hanna Instruments HI 96770C Скачать руководство пользователя страница 4

4

degree Celsius
US Environmental Protection Agency
degree Fahrenheit
Liquid Crystal Display
milligrams per liter. mg/L is equivalent to ppm (part per million)
milliliter
millivolts

°C

:

EPA

:

°F

:

LCD

:

mg/L

:

mL

:

   

mV

:

The 

HI 96770 

is an auto diagnostic portable microprocessor meter that benefits from 

HANNA

’s

years of experience as a manufacturer of analytical instruments. It has the advanced optical system
based on a Light Emitting Diode (LED) and a narrow band interference filter that allows most accurate
and repeatable readings. All instruments are factory calibrated and the electronic and optical design
minimizes the need of frequent calibration.
With the powerful CAL CHECK

 

validation

 function, you are able to validate good performance of your

instrument at any time. The validation procedure is extremely user friendly. Just use the exclusive

HANNA

 ready-made, NIST traceable standards to verify the performance of the instrument and

recalibrate if necessary.
The instrument is splash waterproof and the LED and filter units are protected from dust or dirt by a
transparent cup. This makes the instruments fulfill field applications. Display messages aid the user in
routine operation. The meter has an auto-shut off feature that will turn off the instrument after 10
minutes of non use in 

measurement mode

 or after 1 hour if left in  

calibration mode

.

The meter uses an exclusive positive-locking system to ensure that the cuvet is in the same position
every time it is placed into the measurement cell. It is designed to fit a cuvet with a larger neck
making it easier to add both sample and reagents. The cuvet is made from special optical glass to
obtain best results.
The 

HI 96770

 meter measures the molybdate reactive silica (SiO

2

) content in water samples in the 0

to 200 mg/L (ppm) range. The method is an adaption of the USEPA METHOD 370.1 for drinking,
surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO

2

 C.

The reagents are in

 

powder form and are supplied in packets. The amount of reagent is precisely dosed

to ensure the maximum repeatability.

GENERAL DESCRIPTION

ABBREVIATIONS

Содержание HI 96770C

Страница 1: ...1 w w w h a n n a i n s t c o m This Instrument is in Compliance with the Directives Instruction Manual HI 96770C Silica High Range ISM...

Страница 2: ...ESSORIES 22 WARRANTY 23 Dear Customer Thank you for choosing a HANNA product This manual will provide you with the necessary information for the correct use of the instrument Please read it carefully...

Страница 3: ...h Two Sample Cuvets and Caps Two CAL CHECK standard cuvets HI 96770 11 with Quality Certificate 9V Battery Scissors Tissues for wiping cuvets Instrument Quality Certificate Instruction Manual and Quic...

Страница 4: ...The instrument is splash waterproof and the LED and filter units are protected from dust or dirt by a transparent cup This makes the instruments fulfill field applications Display messages aid the use...

Страница 5: ...er Dimensions 192 x 102 x 67 mm 7 6 x 4 x 2 6 Weight 290 g 10 oz REQUIRED REAGENTS Code Description Quantity test HI 96770A 0 Silica HR Reagent A 1 packet HI 96770B 0 Silica HR Reagent B 1 packet HI 9...

Страница 6: ...lar concentration of the substance d optical path through the substance Therefore the concentration c can be calculated from the absorbance of the substance as the other factors are known Photometric...

Страница 7: ...measuring unit and to display it on the LCD The measurement process is carried out in two phases first the meter is zeroed and then the actual measurement is performed The cuvet has a very important...

Страница 8: ...ation and measurement Calibration mode may be entered by keeping CAL CHECK pressed for three seconds the CAL tag appears it enables calibration of the instrument GLP mode may be entered by pressing GL...

Страница 9: ...ht Low There is not enough light to perform a measurement Please check the preparation of the zero cuvet No Light The instrument cannot adjust the light level Please check that the samples does not co...

Страница 10: ...ing is out of range Cap error the cuvet is not inserted correctly and an excess ambient light is reaching the detector If the cover is properly installed then contact your dealer or the nearest Hanna...

Страница 11: ...be dry outside and completely free of fingerprints oil or dirt Wipe it thoroughly with HI 731318 or a lint free cloth prior to insertion Shaking the cuvet can generate bubbles in the sample causing hi...

Страница 12: ...ing ON OFF and follow instruction manual to perform either the MEASUREMENT VALIDATION or CALIBRATION PROCEDURE When the beeper sounds and the LCD displays dashes the meter is ready The blinking ZERO i...

Страница 13: ...tion Remove the cap and add the content of one packet of HI 96770B 0 Silica HR reagent B Replace the cap and shake vigorously vigorously vigorously vigorously vigorously until complete dissolution unt...

Страница 14: ...t the notch on the cap is positioned securely into the groove Wait for 2 minutes and then press READ READ READ READ READ TIMER TIMER TIMER TIMER TIMER The instrument status indicator will appear depen...

Страница 15: ...eter is ready INTERFERENCES Iron Fe2 and Fe3 interferes at high levels Sulfide S2 interferes at high levels Phosphates does not interfere up to 50 mg L PO4 3 VALIDATION PROCEDURE Use the validation pr...

Страница 16: ...nd the instrument status indicator together with CAL CHECK will appear on the display depending on the measurement phase The display will show the validation standard value The reading should be withi...

Страница 17: ...st at room temperature 18 to 25 C 64 5 to 77 0 F Turn the meter on by pressing ON OFF When the beeper sounds and the LCD displays dashes the meter is ready Enter the calibration mode by holding CAL CH...

Страница 18: ...hase After measurement the instrument will show for three seconds the Cal Check Standard value Note If the display shows STD HIGH the standard value was too high If the display shows STD LOW the stand...

Страница 19: ...s been set press ZERO CFM or READ TIMER to confirm Nowthedisplaywillshowthemonthblinking Press GLP to edit the desired month 01 12 If the key is kept pressed the month number is automatically increase...

Страница 20: ...sulted and the factory calibration can be restored To display the calibration date Press GLP to enter GLP mode The calibration month and day will appear on the main display and the year on the seconda...

Страница 21: ...One fresh battery lasts for around 750 measurements depending on the light level The remaining battery capacity is evaluated at the instrument startup and after each measurement The instrument display...

Страница 22: ...battery follow the steps REAGENT SET REAGENT SET REAGENT SET REAGENT SET REAGENT SET HI96770 01 Reagents for 100 SILICA HIGH RANGE tests HI96770 03 Reagents for 300 SILICA HIGH RANGE tests OTHER ACCE...

Страница 23: ...intained according to the instructions This warranty is limited to repair or replacement free of charge Damages due to accident misuse tampering or lack of prescribed maintenance are not covered If se...

Страница 24: ...2 4 MAN96770CR1 01 07 w w w h a n n a i n s t c o m...

Отзывы: