Hanna Instruments HI 93703 Скачать руководство пользователя страница 10

19

18

Battery replacement must only take place in a
safe area and using the battery types specified
in this instruction manual.

To install or replace the
batteries, turn the unit off
and unscrew the 2 screws
located on the back of the
meter.

Remove the battery cover
and insert the new batteries
in the compartment while
paying attention to the po-
larity.

After the batteries have
been installed, close the
battery cover and tighten
the 2 screws.

BATTERY REPLACEMENT

All components have been selected to mini-
mize current drain without compromising func-
tionality.

In order to minimize the battery consumption,
the meter is equipped with an auto-off function
which switches the meter off after 5 minutes of
non-use.

The power source are 4 alkaline batteries (1.5V
AA) with an expected life of 60 hours, or 900
measurements.

To always grant accurate measurements, the
batteries are monitored to ensure that readings
are not taken when there is insufficient power.
A "LO BAT" indication will appear on the lower
right corner of the display when the batteries are
weak and require replacement. The instrument
can still perform approx. 50 measurements.

A "-BA-" indication will appear on the display
when the batteries are too weak to perform
reliable measurements. The message appears
for a few seconds, and then the meter will
automatically switch off. Batteries must be
immediately replaced.

Содержание HI 93703

Страница 1: ...1 Instruction Manual HI 93703 PortableMicroprocessor TurbidityMeter...

Страница 2: ...rument is in compliance with the directives TABLEOFCONTENTS Preliminaryexamination 3 Generaldescription 3 Principleofoperation 5 Functionaldescription 6 Specifications 7 Operationalguide 8 Measurement...

Страница 3: ...ery life theinstrumentisequipped with an automatic shut off feature which is activated after 4 minutes of non use The meter is very simple to use all operations can be carried out with only four keys...

Страница 4: ...attery Life Approx 60 hours of use or 900 measurements Auto off After 5 minutes of non use Environment 0 to 50 C 32 to 122 F RH max 95 non condensing Dimensions 220 x 82 x 66 mm 8 7 x 3 2 x 2 6 Weight...

Страница 5: ...ue will ap pear after approxi mately 25 seconds OPERATIONALGUIDE To prepare the instrument for taking measurements first install the batteries see Battery Replacement section on page 17 and then turn...

Страница 6: ...erting vials into the instrument wipe them with HI 93703 70 soft lint free tissue Handle vials so that no fingerprints can get on the areas where light passes ap proximately 2 cm 1 inch from the botto...

Страница 7: ...ationcan be editednowbysim ply pressing the DATE key To scroll to the correct number press the READ key The de fault blinking param eter is the month on the left hand of the display MM DD SOURCESOFINT...

Страница 8: ...maintained To confirm the dis played data values and to go to the next step press the CAL key once A blinking ZERO message will appear Take the HI 93703 0 bottle containing the ZEROFTU Standard or tur...

Страница 9: ...lable upon request VIEWINGTHECALIBRATIONDATE Turnthemeteronand wait for the display to show Press and hold the DATE key and a MM DD message appearswhilethekey is held Note The displayed date is the da...

Страница 10: ...nimize the battery consumption the meter is equipped with an auto off function which switches the meter off after 5 minutes of non use Thepowersourceare4alkalinebatteries 1 5V AA with an expected life...

Страница 11: ...tions Themeterisin areadystate andmeasurementorcalibra tioncanbeperformed Calibration mode is active IftheCALkeyisnotpressed within6seconds themeter will automatically switch to themeasurementmode Cal...

Страница 12: ...ges due to acci dents misuse tampering or lack of prescribed mainte nance are not covered If service is required contact the dealer from whom you purchased the instrument If under warranty report the...

Страница 13: ...258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011 615 8582 Taiwan Tel 886 2 2739...

Отзывы: