5.  GENERAL OPERATIONS

Turning the Tester On & Off

•  Turn the tester face down. Rotate the battery cover on the back of the tester counterclockwise and set it aside. Remove 

the battery insulation film.

•  Press the ON/OFF button to turn the tester on or off. Initialization screen displays all LCD segments, followed by the 

battery percentage. The tester enters measurement mode. Before the tester turns off, “

OFF

 

PWR

” is displayed briefly.

•  Press and hold the ON/OFF button to turn the tester off when connected to Bluetooth.

Battery Replacement

1.  Turn off the tester. 

2.  Turn the tester face down and rotate the battery cover counterclockwise. Set it aside.

3.  Press the metallic pin to push old battery out.

4.  Place the new battery with positive (+) sign facing out.

5.  Reset the date and time in the setup menu or connect to the Hanna Lab App to update it 

automatically.

6.  Align the mark on the cover with the open lock icon ( ) on the case. Rotate the cover 

clockwise until the mark on the cover aligns with the closed lock icon ( ).

Note:

 Only use specified battery type. Dispose of old battery in accordance with local regulations.

6.  SETUP

The Setup button is located inside the battery compartment. After Setup configuration, replace the cover.

Setup Menu Navigation

•  Press the Setup button to enter Setup mode and navigate menu items.

•  To exit Setup mode, press the Setup button after “

SEt

 

TIME

” option is displayed.

•  Press the ON/OFF button to configure menu item options.

Temperature Unit 

Option:

 °C or °F

Press ON/OFF button to select desired 

temperature unit.

°C

T E M P

 

°F

TEMP

Auto-Off Interval

Option:

 8, 60 min., or “

----

” (disabled)

To save battery life, after the selected 

auto-off interval has elapsed, the tester will 

automatically turn off. Press ON/OFF button to 

select desired interval.

8

AOFF

 

60

AOFF

 

----

AOFF

Buffer Set

Option:

 7.01 pH (Hanna) or 6.86 pH (NIST)

Press ON/OFF button to select the calibration 

buffer set (Hanna or NIST).

7.01

BUFF

 

6.86

BUFF

pH Resolution

Option:

 0.01 pH or 0.1 pH

Press the ON/OFF button to select resolution.

0.01

RES

 

0.1

RES

Bluetooth Mode

Option:

 On, PAIr, or OFF

Press ON/OFF button to select Bluetooth 

option at start-up.

&

On

BLU

 

&

PAIr

BLU

 

&

OFF

BLU

Metallic pin

Содержание Gro Line HALO 2

Страница 1: ...INSTRUCTION MANUAL HI9810302 Wireless pH Tester for Soil with built in specialized electrode ...

Страница 2: ...g a Hanna Instruments product Please read this instruction manual carefully before using this instrument This manual will provide you with the necessary information for correct use of this instrument as well as a precise idea of its versatility If you need additional technical information do not hesitate to e mail us at tech hannainst com or view our contact list at www hannainst com Dear Customer...

Страница 3: ...pH Resolution 6 Bluetooth Mode 6 Bluetooth Pairing 7 Date Time 7 7 Bluetooth 7 8 Hanna Lab Application 7 Tag a Measurement 7 9 Calibration 7 Preparation 7 Procedure 7 Stand Alone Tester Up to Three Point Calibration 8 With Hanna Lab App Up to Four Point Calibration 8 10 Measurement 8 11 Care Maintenance 8 Refilling the Electrode 9 Storage 9 12 Warning Error Messages 9 13 Accessories 9 Certificatio...

Страница 4: ... supplied accessories 2 SPECIFICATIONS Range pH 0 00 to 12 00 pH mV pH mV conversion Temperature 0 0 to 60 0 C 32 0 to 140 0 F Resolution pH 0 01 or 0 1 pH mV 0 1 or 1 mV Temperature 0 1 C 0 1 F Accuracy pH 0 05 pH Temperature 0 5 C 0 9 F Calibration Up to three points or four points Automatic buffer recognition with Standard buffers Hanna pH 1 68 4 01 7 01 10 01 or NIST pH 1 68 4 01 6 86 9 18 Tem...

Страница 5: ...ochlorite ultraviolet light and fungal growth the PVDF body also has high abrasion resistance and mechanical strength The conical tip allows for easy penetration into solids and semisolids The PVDF outer junction sleeve can be removed and cleaned Once cleaned a small amount of supplied gel electrolyte is added and the junction is refreshed improving the measurement and extending the life of the te...

Страница 6: ...on the cover aligns with the closed lock icon Note Only use specified battery type Dispose of old battery in accordance with local regulations 6 SETUP The Setup button is located inside the battery compartment After Setup configuration replace the cover Setup Menu Navigation Press the Setup button to enter Setup mode and navigate menu items To exit Setup mode press the Setup button after SEt TIME ...

Страница 7: ... and download information Consult the Help section of the application for information on calibration measurement data logging and sharing When the tester is in discoverable mode it will appear in the list of Available Devices Within the application tap Connect to pair the tester with the device All readings are transmitted directly to the application Tag a Measurement Once connected to the applica...

Страница 8: ...ect testing in the soil without taking samples or creating a slurry 1 Inspect the pH probe to ensure the bridge electrolyte gel has not dried out Refill if necessary 2 Calibrate the pH probe 3 Using an auger HI721319 make a 20 mm 0 78 hole down into the soil The hole needs to be the same depth each time to avoid pH discrepancies 4 Add some distilled or deionized water to the hole the soil should b...

Страница 9: ...he glass tip and the junction hydrated If storage solution is not available pH 4 01 or pH 7 01 buffer can be used Do not store the electrode in distilled or deionized water 12 WARNING ERROR MESSAGES WRNG WRNG displayed during calibration Invalid buffer Check the buffer value and use fresh buffer 12 02 23 7 Measured value displayed blinking Measured value is out of electrode range Clean the electro...

Страница 10: ...for its intended purpose and maintained according to instructions This warranty is limited to repair or replacement free of charge Damage due to accidents misuse tampering or lack of prescribed maintenance is not covered If service is required contact your local Hanna Instruments office If under warranty report the model number date of purchase serial number and the nature of the problem If the re...

Страница 11: ...a is likely to cause harmful interference in which case users are required to correct the interference at their own expense Canada ISED IC 12208A 04 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause ...

Страница 12: ...World Headquarters Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA www hannainst com MAN9810302 Printed in ROMANIA ...

Отзывы: