Recommendations for Users

Before using this product, make sure it is entirely suitable for your specific application and for the 
environment in which it is used. Any variation introduced by the user to the supplied equipment may 
degrade the meters’ performance. For yours and the meter’s safety do not use or store the meter in 
hazardous environments.

Warranty

The meter is warranted for a period of one year against defects in workmanship and materials when 
used for their intended purpose and maintained according to instructions. This warranty is limited to 
repair or replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed 
maintenance is not covered. If service is required, contact your local Hanna Instruments Office. If under 
warranty, report the model number, date of purchase, serial number and the nature of the problem. If the 
repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to 
be returned to Hanna Instruments, first obtain a Returned Goods Authorization (RGA) number from the 
Technical Service department and then send it with shipping costs prepaid. When shipping any instrument, 
make sure it is properly packaged for complete protection.

INSTRUCTION MANUAL

To change the CR2032 Li-ion battery, turn the battery cover located on the back of the meter 
counterclockwise to unlock. Remove cover and replace the battery with + side facing up.

Note: Batteries should only be replaced in a safe area using the battery 

type specified in this instruction manual. Old batteries should be disposed in 

accordance with local regulations.

Battery Replacement

HI981034 

 

Milk

 

pH Tester

IST981034   05/18-1

The meter features a low battery indicator. When 
the battery is running low, the tag will blink on 
screen. When the battery has been depleted, 
“Erb” will appear on screen and the meter will 
turn off.

Place meter in calibration mode. Press and hold 
ON/OFF until “CLr” is displayed. The meter will 
now be at default calibration.

Clear Calibration

“Err” Message

Battery Indicator

From measurement mode, press and hold the  
ON/OFF button. The meter will cycle through 
“OFF,” “CAL,” then current auto-off setting.

The default setting is 8 minutes (“d08”). Press 
ON/OFF button to change. “d60” is auto-off after 
60 minutes, and “d--” disables the auto-off 
feature. Press and hold the button to exit the 
menu.

Auto-off

Electrode Storage Solution

Code

Description

HI70300L

Electrode storage solution, 500 mL bottle

HI70300M

Electrode storage solution, 230 mL bottle

HI9072

Electrode storage solution, 13 mL dropper

Electrode Cleaning Solution

Code

Description

HI700601P

General purpose cleaning solution, 20 mL sachets (25 pcs.)

HI700640P

Cleaning solution for milk deposits, 20 mL sachets (25 pcs.)

HI700641P

Cleaning and disinfection solution for dairy products, 
20 mL sachets (25 pcs.)

pH Buffer Solution

Code

Description

HI70004P

pH 4.01 buffer solution, 20 mL sachets (25 pcs.)

HI70007P

pH 7.01 buffer solution, 20 mL sachets (25 pcs.)

HI77400P

pH 4.01 & 7.01 buffer solution, 20 mL sachets (10 pcs., 5 ea.)

Accessories

Care and Maintenance

To obtain the highest accuracy for measurements it is important to follow these tips:

•  Calibration is only as good as the buffer being used. The pH buffer values change over 

time once the sachets are opened. Fresh buffer should be used for each calibration.

•  The probe should be rinsed with purified water each time before placing in buffer or 

sample to be tested.

•  When the meter is not in use it is important to add several drops of storage solution 

to the protective cap to keep the probe hydrated. If storage solution is not available, 
pH 4.01 or pH 7.01 buffer can be used.

•  For improved accuracy it is recommended to calibrate in two buffers.
•  It is important to calibrate and measure samples at the same temperature. A dramatic 

change in temperature between buffer solutions and samples to be tested will give 
inaccurate readings

.

•  If fouled, clean the electrode by soaking in cleaning solution for 20 minutes, then 

rinse the tip and soak in storage solution at least 30 minutes before use. Recalibrate 
after each cleaning.

In calibration mode, if the meter displays an 
“Err” message when in the correct fresh buffer 
solution then the probe should be cleaned.  
Place the probe in the

 HI700640 

cleaning 

solution for 20 minutes. Rinse with purified water 
and place in storage solution for a minimum of 
30 minutes before calibrating.

Certification

All Hanna Instruments conform to the 

CE European Directives

.

Disposal of Electrical & Electronic Equipment.

 The product should not be treated as household 

waste. Instead hand it over to the appropriate collection point for the recycling of electrical and electronic 
equipment which will conserve natural resources.

Disposal of waste batteries.

 This product contains batteries, do not dispose of them 

with other household waste. Hand them over to the appropriate collection point for recycling.
Ensuring proper product and battery disposal prevents potential negative consequences for the 
environment and human health. For more information, contact your city, your local household waste 
disposal service, the place of purchase or go to 

www.hannainst.com

.