Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before using the instrument.
This manual will provide you with the necessary information for correct
use of the instrument, as well as a more precise idea of its versatility.
If you need additional technical information, do not hesitate to e-mail
us at [email protected].

WARRANTY .................................................................................. 2
PRELIMINARY EXAMINATION ........................................................ 3
GENERAL DESCRIPTION ................................................................ 3
SPECIFICATIONS OF 

HI 9241S

..................................................... 4

SPECIFICATIONS OF 

HI 93501 & HI 93501S

............................... 5

SPECIFICATIONS OF 

HI 93503

..................................................... 6

SPECIFICATIONS OF 

HI 935007

................................................... 7

OPERATIONAL GUIDE ................................................................... 8
BATTERY REPLACEMENT ............................................................. 11
TEMPERATURE PROBES .............................................................. 12

HI 9241, HI 93501, HI 93501S, HI 93503

 and 

HI 935007 

are

guaranteed for two years against defects in workmanship and materi-
als when used for their intended purpose and maintained according
to instructions. Electrodes and probes are guaranteed for six months.
This warranty is limited to repair or replacement free of charge.
Damage due to accidents, misuse, tampering or lack of prescribed
maintenance is not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of
purchase, serial number and the nature of the problem. If the repair is
not covered by the warranty, you will be notified of the charges
incurred. If the instrument is to be returned to Hanna Instruments,
first obtain a Returned Goods Authorization number from the Technical
Service department and then send it with shipping costs prepaid.
When shipping any instrument, make sure it is properly packed for
complete protection.

WARRANTY

TABLE OF CONTENTS

Содержание Foodcare HI 9241

Страница 1: ...1 Instruction Manual HI 9241 HI 93501 HI 93501S HI 93503 HI 935007 Portable Microprocessor Thermometers w w w h a n n a i n s t c o m...

Страница 2: ...nst defects in workmanship and materi als when used for their intended purpose and maintained according to instructions Electrodes and probes are guaranteed for six months This warranty is limited to...

Страница 3: ...93501 HI 93501S HI 93503 and HI 935007 are professional rugged and waterproof thermometers designed to be used on a daily basis in industrial kitchens and catering They provide excellent accuracy and...

Страница 4: ...50 0 to 150 0 C Resolution 0 1 C Accuracy 0 4 C excluding probe error Typical EMC Deviation 0 5 C with HI 765BL probe Battery 3 x 1 5V AAA approx 2000 hours of continuous use Auto off after 8 minutes...

Страница 5: ...ff capability Waterproof casing Range 50 0 to 150 0 C Resolution 0 1 C Accuracy 0 4 C excluding probe error Typical EMC Deviation 0 4 C with HI 762PWL probe Battery 3 x 1 5V AAA approx 2000 hours of c...

Страница 6: ...capability Waterproof casing Range 50 0 to 150 0 C Resolution 0 1 C Accuracy 0 4 C excluding probe error Typical EMC Deviation 0 4 C with HI 765PWL probe Battery 3 x 1 5V AAA approx 2000 hours of cont...

Страница 7: ...asing SPECIFICATIONS OF HI 935007 Range 50 0 to 199 9 C 200 to 1350 C Resolution 0 1 C up to 199 9 C 1 C outside Accuracy 0 2 F S excluding probe error Typical EMC Deviation 3 C Battery 3 x 1 5V AAA a...

Страница 8: ...CD segments for a few seconds followed by the percentage indication of the remaining battery life then it enters Cal Check mode and then enters measurement mode Note The full display can be frozen by...

Страница 9: ...n if necessary HOLD FEATURE HI 93501S HI 93503 The hold function is activated by pressing the HOLD key The measured temperature and the stabil ity bargraph is held on the display until HOLD is pressed...

Страница 10: ...ES NO PROBE message If the probe is not connected NO PROBE message is displayed DAMAGED PROBE message When the readings are very far from the reading range the probe can be dam aged DAMAGED PROBE mess...

Страница 11: ...iately replace the batteries with new ones Battery replacement must only take place in a non hazardous area The batteries are accessed by opening the battery compartment cap on the bottom of the instr...

Страница 12: ...id probe w 1 m 3 3 cable black handle HI 762L General purpose liquid probe w 1 m 3 3 cable white handle HI 762L 2 General purpose liquid probe w 2 m 6 6 cable white handle HI 762L 10 General purpose l...

Страница 13: ...purpose penetration probe w 1 m 3 3 cable blue handle HI 765PBL 10 General purpose penetration probe w 10 m 33 cable blue handle HI 765PG General purpose penetration probe w 1 m 3 3 cable green handl...

Страница 14: ...14 places w 10 m 33 cable FOR HI 935007 HI 766C Penetration K type thermocouple probe w 1 m 3 3 cable To be replaced only by authorized service technicians...

Страница 15: ...e instruments in residential areas could cause unacceptable interferences to radio and TV equipment requiring the operator to follow all necessary steps to correct interferences Any variation introduc...

Страница 16: ...0 Hanna Instruments Inc Highland Industrial Park 584 Park East Drive Woonsocket RI 02895 USA Technical Support for Customers Tel 800 426 6287 Fax 401 765 7575 E mail tech hannainst com www hannainst c...

Отзывы: