SETUP
Startup Delay (Automatic Control Only)
Option:
user selectable
Startup delay represents the delay to start dosing at power-on.
Press the arrow keys to change the time values.
"STARTUP DELAY SEC" message is scrolled on the bottom of the LCD screen.
Note:
To enter Startup Delay screen, pump control mode must be set as Auto.
Overtime Alarm
Option:
user selectable
Press the arrow keys to change the time values. Overtime alarm range is from 1 to 180 minutes.
To disable the alarm, select Off.
"OVERTIME ALARM MIN" message is scrolled on the bottom of the LCD screen.
Note:
To enter Overtime alarm screen, pump control mode must be set as Auto.
Flow Rate
Option:
user selectable
Press the arrow keys to change the values.
When in On/Off automatic control mode, the displayed value represents the actual flow rate.
When in Proportional automatic control mode, the displayed value represents a 100% flow rate.
"FLOW RATE L/H" or "FLOW RATE G/H" message is scrolled on the bottom of the LCD screen.