4.When using a forklift to move the equipment, make sure the equipment is stable and

<200mm above the ground, and make sure to avoid the equipment casters.

5.When using an overhead crane to move the equipment, use a wire rope to hold the

equipment in a stable position before moving.

11.2 Storage requirements

When the equipment is not used for a long time, please drain the coolant from the equipment

and use compressed air to drain the coolant from the pump, filter and pipeline, wipe off the water

and oil, pack the equipment with winding film to prevent dust and water, and place it in a cool and

ventilated place without direct sunlight and dust gathering.

Storage environment conditions, temperature: 0~60℃, relative humidity: ≤90%.

12. Other instructions

12.1 Service support
12.1.1 Warranty coverage

Within 24 months from the date of purchase of the product from our company, the

failure obviously caused by the design defect or quality problems arising from manufacturing, the

company provides free repair and replacement parts.

The warranty period expires, lifetime paid maintenance.

12.1.2 Non-warranty range of cases

Not in accordance with the instructions for installation, use and maintenance or use of

power and other external conditions do not meet the requirements

Damage caused by the external conditions such as power supply does not meet the

requirements.

Damage not caused by our company's poor transportation and storage.
Damage caused by the modification of our products or other human factors.

Damage caused by human force majeure factors. For example: natural disasters, war, etc.
Damage caused by installation on vehicles and ships or use abroad.

Damage caused by equipment failure.

12.2 Other matters

The power supply should be installed according to the national wiring standard

specification (voltage, frequency, and differential pressure should be met)

If the power cord is damaged, to avoid danger, it must be replaced by the manufacturer's

maintenance department, or professional personnel in similar department to replace.

The power must be turned off for 3 minutes before repairing.

Содержание HL-1000 Series

Страница 1: ...0 2000 3000 Series SCL 1500 2000 3000 Series SCHYTJ 1500 2000 3000 Series SY 1500 2000 Series User s Manual of Fiber Laser Chiller WUHAN HANLI REFRIGERATION TECHNOLOGY CO LTD Add No 1 Second Road XinF...

Страница 2: ...6 4 1 Add water 15 6 4 2 Exhaust and drainage 15 6 5 Warm Tips 16 7 Product use 16 7 1 Inspection before commissioning 16 7 2 Introduction to controller panel 16 7 2 1 Introduction to Hanli split con...

Страница 3: ...ne maintenance 22 9 Fault analysis and troubleshooting 23 10 Circuit diagram 25 11 Transportation and storage 27 11 1 Transport requirements 27 11 2 Storage requirements 27 12 Other instructions 27 12...

Страница 4: ...f product information and product improvements are the final interpretation of the company without prior notice and the updated content will be compiled into the reprinted manual If you have any quest...

Страница 5: ...ented It must be cut off for 3 minutes before it can work Scrap Must be implemented When the equipment has reached its service life and needs to be scrapped it must be disposed of with industrial garb...

Страница 6: ...ge occurs please be sure to get some air and ventilation Otherwise a large amount of refrigerant filled with closed space will produce anesthesia to the human body and cause asphyxiation risk b Avoid...

Страница 7: ...e air filter at least once a week If the air filter is obstructed the refrigeration capacity will be reduced the power consumption will increase and even the alarm will not work properly Keep surface...

Страница 8: ...ture and high pressure gas and discharges it to the condenser to condense and release heat into a high pressure liquid The low temperature and low pressure super cooled liquid is vaporized by the evap...

Страница 9: ...mbient temperature a Operating range of Pure Softened Water Ambient temperature b Operating range of anti freeze water FIG 2 Operation range of equipment Note The above operating range is obtained in...

Страница 10: ...re equipped with water filters and double temperature and two channels of water supply For example SCH 1500 represents a handheld welding chiller with a matching laser power of 1500W which is equipped...

Страница 11: ...SCH 1500 220V 50Hz 2 1 R32 0 27 20 5 2 41 760 485 430 13 15 SCH 2000 220V 50Hz 2 5 R32 0 36 27 5 2 43 760 485 430 13 16 SCH 3000 220V 50Hz 3 9 R32 0 53 51 2 60 850 485 577 13 17 SCL 1500 220V 50Hz 2...

Страница 12: ...wheels shall be locked for equipment with caster No shielding shall be allowed in the air inlet within the range of 1 5m and the air outlet within the range of 2 0m so as not to affect the heat dissi...

Страница 13: ...ser Chiller 13 FIG 3 Requirements for equipment installation form FIG 4 Equipment installation space requirements FIG 5 Environmental requirements for equipment installation Air suction Air suction Ex...

Страница 14: ...p supply pressure Fig 6 Connection diagram of chiller and laser 6 3 Circuit connection 1 Please refer to the wiring label of the chiller when wiring 2 Recommended reference standard for power cord dia...

Страница 15: ...ischarge air until water flows out and then tighten the air exhaust screw plug see Figure 8 in which only the exhaust positions of vertical pump and horizontal pump are shown According to customer req...

Страница 16: ...vel is in the standard zone Verify that the power supply form matches the product nameplate the 380V power line is three phase and five wire and that the 220V power supply The line is a single phase t...

Страница 17: ...sor operating flashing cooling demand Off compressor off Low temperature water heating Heating1 Illuminated low temperature water heating active extinguished low temperature water heating off Ambient...

Страница 18: ...eating off Switching to the low temperature water interface indicates low temperature water heating switching to the ambient water interface indicates ambient water heating Solenoid valves Valve Does...

Страница 19: ...et temperature 7 5 Parameter setting 7 5 1 Parameter setting of the split controller In the non fault state press at the same time to enter the low temperature water setting temperature setting interf...

Страница 20: ...nquiry Reset Fault When a fault occurs an alarm appears in the main interface and the fault is queried and reset as follows 8 Maintenance The equipment must be stopped and cut off after 3 minutes for...

Страница 21: ...and the freezing point prevented is equal to the ambient temperature at which the equipment is located minus approximately 5 C When the average daily temperature is above 5 C replace the water contai...

Страница 22: ...edium in 15 20 days the cooling medium must be pure distilled or high purity water Checking water connections for looseness and pump leaks Inspection of the water tank and cleaning of the dirt deposit...

Страница 23: ...C Condensing fan not running D Too much dust in the filter E Damaged pressure switch Stop the compressor not the pump A Clear the surrounding clutter B Checking for leaks C Check the fan D Cleaning th...

Страница 24: ...or adhesion E12 Room temperature water Flow alarms A Clogged normal temperature water line B reversed inlet and outlet connections C Leakage in ambient water line D Damaged flow switch Stop electric h...

Страница 25: ...ns Automatic Water flow switch Alarm Alarm power failure heating Automatic Water level switch alarm Power up detection Alarm power failure heating Automatic Water level switch Alarm Power up detection...

Страница 26: ...troller Passive output signal Normal temperature water flow switch Low temperature water Normal temperature water alarm pump By pass valve compressor Low temperature water heating Normal temperature w...

Страница 27: ...r handling do not bump or tilt excessively not more than 45 avoid bumping hitting and overturning 2 When moving the equipment use the proper tools such as a forklift or overhead crane and do not carry...

Страница 28: ...quality problems arising from manufacturing the company provides free repair and replacement parts The warranty period expires lifetime paid maintenance 12 1 2 Non warranty range of cases Not in accor...

Отзывы: