ELECTRICAL SCHEMATIC

575-460/3/60 Transformer Pack

X1

L3 

PE 

L2

L1 

PE 

L3 

L2 

L1 

H1 

G

H3

G

X2 X3 X4

H2 

H4

X1

H1 

H3

X2 X3 X4

H2 

H4

RD

G/Y

WH

BL

WIRING ASSEMBLY DETAIL

RD

G/Y

WH

BL

TRANSFORMER 2

TRANSFORMER 1

575V-460V

HES800-1750, HPRP1000-1500

575V CUSTOMER

CONNECTION

460V TERMINAL

CONNECTION

X1

L3 

PE 

L2

L1 

PE 

L3 

L2 

L1 

H5

H1

G

H5

X1

H1

G

RD

G/Y

WH

BL

WIRING ASSEMBLY DETAIL

RD

G/Y

WH

BL

TRANSFORMER 2

TRANSFORMER 1

575V-460V

HES2000-3000, HPRP1750-3000

H6 H7 

H3

X2 X3 X4

H2 

H4

575V CUSTOMER

CONNECTION

460V TERMINAL

CONNECTION

H6 

H3

X2 X3 X4

H2 

H4

H7 H8 

H8

WIRING ASSEMBLY DETAIL

575V-460V

Models 2000-3000

WIRING ASSEMBLY DETAIL

575V-460V

Models 800-1750

Содержание SPX FLOW HES Series

Страница 1: ...mpressed Air Dryers Models HES800 HES1000 HES1250 HES1500 HES1750 HES2000 HES2500 HES3000 FOR M NO 5001364 R EVI S ION 12 2017 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT I N STR UCTION MAN UAL ...

Страница 2: ...3 1 Monthly Maintenance 14 3 2 Annual Maintenance 14 4 0 TROUBLESHOOTING GUIDE 16 5 0 REFERENCE Sizing 17 Engineering Data Table 18 19 Dryer Set Point Table 20 Dryer Alarm Table 21 Controller Screen Shots Status Menu Screens 22 Setup Menu Screens 23 Network Menu Screens 24 6 0 DIMENSIONS WEIGHTS 25 7 0 ELECTRICAL SCHEMATIC Model 800 26 27 Models 1000 and 1250 28 29 Models 1500 and 1750 30 31 Model...

Страница 3: ... weather Damage to electrical and control components may result IMPORTANT WATER COOLED UNITS If unit is shut down in below freezing temperatures the water cooled condenser may freeze and cause permanent damage Condenser must be drained when the unit is shut down IMPORTANT Do not store dryer in temperatures above 130 F 54 C GENERAL SAFETY INFORMATION 1 PRESSURIZED DEVICES This equipment is a pressu...

Страница 4: ...ront of dryer E Standard units are designed to operate in ambients Air cooled 40 to 110 F 4 to 43 C Water cooled 40 to 130 F 4 to 54 C F Dryer is designed to operate at all altitudes no adjustment for altitude is required G The installation of a flexible connection prior to the dryer is recommended to prevent possible damage from vibration NOTE Outdoor installation Standard units are designed for ...

Страница 5: ...ate may contain oil Comply with applicable laws concerning proper disposal D Verify that isolation valves are open If the drain fails to discharge after the valve is energized the electronic control circuit will repeatedly energize the valve in an attempt to clear the discharge port If after 60 seconds the drain still fails to discharge the control circuit then switches to the alarm mode In this m...

Страница 6: ...ature 120 F 49 C D Maximum ambient temperature Air cooled models 110 F 43 C Water cooled models 130 F 54 C E Minimum ambient temperature 40 F 4 C 2 2 Start Up A Energize Dryer Green power on light will illuminate IMPORTANT Energize dryer for 24 hours before refrigeration compressor is started Never use the disconnect switch to shutdown the dryer for an extended period of time except for repair Fai...

Страница 7: ...r leaks 4 After 15 minutes open outlet isolation valve slowly 5 Close air bypass valve 6 Dryer may be operated in Manual or scheduled modes NOTE Check for correct phasing of unit On air cooled models check fan rotation air must be pulled through the condenser Fans may not start immediately or may cycle on and off If rotation is in the wrong direction follow the procedure below On water cooled mode...

Страница 8: ... the termination resistors install jumpers on J12 in the direction shown by the white bars printed above the connector If the jumpers are removed no termination of the RS 485 bus is in effect Usually these jumpers must be in position for proper operation of the bus J10 contains the two wire four wire jumper If the jumper is set in W2 place the circuit is set up for two wire operation If the jumper...

Страница 9: ...mestamped and recorded in the EVENT TXT file stored in the root folder of the USB flash drive 3 USB Bootloader Firmware updates for the EMM connect can be performed via the USB flash drive In order to perform a firmware update place the image hex and lang hex files provided by SPX in the root folder of a USB thumb drive With the dryer controller powered off install the USB flash drive in the USB h...

Страница 10: ...or inlet temperature evaporator outlet tem perature discharge temperature energy savings and any active alarms The navigation bar at the top of this page can be used to view event history dryer scheduler and dryer settings Energy savings is shown as the estimated annual energy savings based on the actual energy cost entered on the settings page and the average dryer load over the last 30 days Figu...

Страница 11: ...ail addresses whenever an alarm or warning occurs on the dryer Figure 4 Settings 2 Modbus TCP The Modbus TCP connection allows you to continuously monitor the dryer from a DCS system which implements a Modbus TCP master The dryer controller implements a ModbusTCP server on port 502 The following Modbus register table provides a list of data that is available ...

Страница 12: ... Reserved 40023 0x0016 RESERVED N A Reserved 40024 0x0017 ENERGY_COST Integer Energy cost Cost kWh 40025 0x0018 AUDIBLE_ALARM Boolean Audible Alarm 0 Disabled 1 Enabled 40026 0x0019 MODBUS_ADDRESS Integer Modbus Address 40027 0x001A FULL_POWER Watts Full load power 40028 0x001B 40029 0x001C 40030 0x001D 40031 0x001E 40032 0x001F 40033 0x0020 ALARM_MSG_1 Integer Alarm message 1 phrase id 40034 0x00...

Страница 13: ...7 0x0080 Phase Reversal 8 0x0100 Phase Loss 9 0x0200 Evaporator Temperature Sensor Failure 10 0x0400 Glycol Temperature Sensor Failure 11 0x0800 Evaporator Outlet Temperature Sensor Failure 12 0x1000 Discharge Temperature Sensor failure 13 0x2000 High Super Heat 14 0x4000 Reserved 15 0x8000 Reserved Dryer Warning Flags Register 40003 Bit Mask Description 0 0x0001 High Evaporator Temperature 1 0x00...

Страница 14: ...0D DEMM 1000 14 0x000E DEMM 1250 15 0x000F DEMM 1500 16 0x0010 DEMM 1750 17 0x0011 DEMM 2000 18 0x0012 DEMM 2500 19 0x0013 DEMM 3000 20 0x0014 Reserved 21 0x0015 Reserved 22 0x0016 Reserved 23 0x0017 Reserved 24 0x0018 Reserved 25 0x0019 Reserved 26 0x001A Reserved 27 0x001B Reserved 28 0x001C Reserved 29 0x001D Reserved 30 0x001E Reserved 31 0x001F Reserved Dryer Mode Register s 40018 Decimal Hex...

Страница 15: ...cription 0 0x0000 English 1 0x0001 Spanish 2 0x0002 French 3 0x0003 German 4 0x0004 Portuguese 5 0x0005 Italian 6 0x0006 Polish 7 0x0007 Danish 8 0x0008 Dutch 9 0x0009 Norwegian 10 0x000A Finnish 11 0x000B Swedish 12 0x000C Czech 13 0x000D Reserved 14 0x000E Reserved 15 0x000F Reserved ...

Страница 16: ...ng of the condensate drain 1 To facilitate service maintenance kits are available C Replace the filter cartridges in the filter All necessary service parts can be ordered in a service kit See Parts List 1 When to replace the Separator Filters Replace filter element when pressure drop across dryer is excessive or annually When removing liquids at rated flow conditions the pressure drop will be 5 ps...

Страница 17: ...ges 4 i Push new cartridges on to the mounting posts in the bottom of the separator vessel NOTE Do not touch the foam sleeves of the cartridges with your fingers j Close housing in reverse order k Put on insulation l Switch on the dryer m Repressurize the dryer by slowly opening the compressed air inlet valve n Slowly open the compressed air outlet valve o Slowly close the compressed air bypass va...

Страница 18: ...ser cooling Air cooled Ambient temperature too high clogged condenser fins obstructed flow across condenser faulty fan motor or fan control switch 2 Water cooled Cooling temperature too high flow too low clogged strainer faulty water regulating valve 1 Dryer overloaded 2 Refrigeration system off or not cooling sufficiently 1 Drain line restricted or frozen 2 Drain mechanism faulty 1 Faulty compres...

Страница 19: ...250 1500 1750 2000 2500 3000 Rated capacity of air cooled models scfm 60Hz 50Hz 800 672 1000 830 1250 1050 1500 1250 1750 1460 2000 1670 2500 2080 3000 2500 TABLE 2 Air capacity correction factors Multipliers INLET COMPRESSED AIR CONDITIONS INLET INLET TEMPERATURES PRESSURES 80 F 90 F 100 F 110 F 120 F psig barg 27 C 32 C 38 C 43 C 49 C 50 80 100 125 150 175 200 3 4 5 5 6 9 8 6 10 3 12 1 13 8 1 35...

Страница 20: ... BTU hr 60 Hz a c 40 800 47 000 58 800 69 000 80 500 98 500 118 800 141 300 50 Hz a c 41 000 47 200 59 000 70 500 82 300 100 300 119 500 143 400 Refrigerant Type R 404A Refrigerant Charge See Data Tag on Dryer Suction Pressure Setting nominal operating range 75 85 psig 5 2 5 9 barg Compressor Pressure Switch Setting cut out cut in High a c 450 350 psig 31 0 24 1 barg High w c 320 250 psig 22 1 17 ...

Страница 21: ...3 Input Power Rated Flow watts 4 710 6 730 7 400 9 770 13 010 14 870 16 840 18 200 Minimum Circuit Ampacity 8 11 11 16 16 19 21 24 Maximum Overcurrent Protector amps 12 17 5 17 5 25 25 30 35 35 Compressor Rated Load Amps 6 7 9 0 9 0 6 7 6 7 6 7 6 7 9 0 6 7 9 0 9 1 9 0 9 1 Compressor Locked Rotor Amps 48 70 70 48 48 48 48 70 48 70 70 70 70 Compressor Winding Resistance ohms 3 64 2 27 2 27 3 64 3 64...

Страница 22: ...ncrement Default Service Interval Hours 0 9999 1 4000 Energy Cost Decimal 0 00 0 99 0 01 0 13 Total Hours Hours 0 999999 1 0 Proportional Gain Gain 0 0 100 0 0 1 3 0 Integral Time Seconds 0 0 200 0 0 1 100 0 Derivative Time Seconds 0 0 200 0 0 1 20 0 Set Value Celsius 0 0 C 32 0 F 15 0 C 59 0 F 0 1 C 0 2 F 3 3 C 37 9 F Time On Minutes 0 0 10 0 0 1 3 0 Time Off Minutes 0 0 10 0 0 1 3 0 Modbus Devic...

Страница 23: ...sed Halt compressors De energize alarm relay 1 EVAPORATOR HIGH TEMPERATURE Evaporator temperature High evaporator temperature set point 1 Second Dryer On 10 minutes Alarm reset button pressed De energize alarm relay 2 HEATER 1 Heater 1 switch open 1 Second Standby Alarm reset button pressed De energize alarm relay 2 HEATER 2 Heater 2 switch open 1 Second Standby Alarm reset button pressed De energ...

Страница 24: ...0 HRS TO SERVICE 4970 xx xx xxxx xx xx MANUAL MODE Version x x DISCHARGE xxx x C xxx F EVAPORATOR IN xxx x C xxx F Up Down EVAPORATOR OUT xxx x C xxx F Up Down DRYER LOAD 0 ENERGY SAVINGS 2108 YEAR Up Down Up Down Hidden if evaporator outlet temperature sensor disabled Hidden if energy cost 0 00 ALARM MESSAGE 1 ALARM MESSAGE 2 Shown for each active alarm Up Down Up Down ...

Страница 25: ...ENU ENERGY COST MAIN MENU AUTO RESTART Down Up Down Up Down Up LANGUAGE ENGLISH Enter DATE TIME 02 24 2011 09 40 Enter SCHEDULE MON ON IGNORE Enter HRS TO SERVICE 4970 Enter 02 24 2011 09 55 ALARM MESSAGE 1 Enter ENERGY COST 0 10 KWH Enter AUTO RESTART DISABLED Enter Down Up Down Up Down Up Down Up Setup Menu Down Up Network Menu MAIN MENU NETWORK MENU Enter NOTE Press hold ESC button for 3 second...

Страница 26: ... MENU IP ADDRESS TYPE Network Menu IP ADDRESS TYPE DYNAMIC Enter NETWORK MENU IP ADDRESS Up Down IP ADDRESS 192 168 0 2 Enter NETWORK MENU SUBNET MASK Up Down SUBNET MASK 255 255 255 0 Enter NETWORK MENU DEFAULT GATEWAY Up Down DEFAULT GATEWAY 192 168 0 1 Enter Up Down NETWORK MENU MODBUS ADDRESS Up Down MODBUS ADDRESS 1 Enter ...

Страница 27: ...62 85 1 8 2162 85 1 8 2162 85 1 8 2162 55 1 8 1400 55 1 8 1400 55 1 8 1400 55 1 8 1400 59 3 8 1508 59 3 8 1508 59 3 8 1508 59 3 8 1508 13 1 4 337 13 1 4 337 13 1 4 337 13 1 4 337 31 1 4 794 31 1 4 794 31 1 4 794 31 1 4 794 9 1 8 232 9 1 8 232 9 1 8 232 9 1 8 232 1940 880 1997 906 2315 1050 2646 1200 6 ANSI Flg 6 ANSI Flg 6 ANSI Flg 6 ANSI Flg NOTE Dimensions and weights are for reference only Requ...

Страница 28: ... 3A L1 3A L3 3 L2 3 L1 3 L1 5A L3 5 L1 5 TB1 20 TB1 19 COMPRESSOR 1 460VAC 3 PH 4HP 6 7 RLA M FAN 1 1 25 KW 460VAC 1 95 FLA M HEATER 1 70W 460VAC 0 15A SET 7A 7 10 AMP 17A F11 K62 17A 1 4 2 AMP SET 2A F13 K43 21 22 K62 MOUNTED ON T22 F22 F22C F22B F22A 1A 1A 1A FU22 1 5A FU22 24V 120V 460V 400V 230V 208V COM FU22 2 N PLEASE NOTE FOR OPERATION 380 400VAC 3PH 50HZ MOVE PRIMARYTO 400VACTAP T22 24 120...

Страница 29: ...14 13 TB2 2 TB2 2 TB2 2 TB2 12 TB2 1 TB2 2 TB2 31 TB2 4 TB2 3 TB2 1 NO COM NO COM TB2 36 OPTIONAL CLSC DRAIN STD DRAIN TEMP 1 FAN 1 S43 1 TB2 31 PRES 1 FAN 1 S43 TB2 2 OX LOCAL REMOTE START STOP REFRIGERANT HI PRES S67 A55 A51 S62 A55 A51 PE IN1 OV N L PE IN1 OV N L UNLOADING SOLENOID A1 A2 A1 A2 A2 A1 9 5 31 32 14 11 44 43 W29 W33COMMON C NC NO C NC NO J2 K43 COMMON DRAINCOMMON CONTROL BOARD A60 ...

Страница 30: ... 3 L3 3 L1 3A L2 3A L3 3A TB1 7 TB1 9 TB1 11 TB1 PE 12 AWG M HEATER 1 70W 460VAC 0 15A COMPRESSOR 1 460VAC 3 PH 6HP 9 0 RLA M FAN 1 1 25 KW 460VAC 1 9 FLA 7 10 AMP SET 9A 17A F11 K62 21 22 K62 K43 1 4 2 AMP SET 2A 17A F13 MOUNTED ON T22 F22 F22C F22B F22A 1A 1A 1A FU22 1 5A FU22 24V 120V 460V 400V 230V 208V COM FU22 2 N PLEASE NOTE FOR OPERATION 380 400VAC 3PH 50HZ MOVE PRIMARYTO 400VACTAP T22 24 ...

Страница 31: ...13 FU22 2 TB2 2 TB2 2 TB2 2 TB2 12 TB2 1 TB2 2 TB2 31 TB2 4 TB2 3 TB2 1 NO COM NO COM TB2 36 OPTIONAL CLSC DRAIN STD DRAIN TEMP 1 FAN 1 S43 1 TB2 31 PRES 1 FAN 1 S43 TB2 2 OX LOCAL REMOTE START STOP REFRIGERANT HI PRES S67 A55 A51 S62 A55 A51 PE IN1 OV N L PE IN1 OV N L UNLOADING SOLENOID A1 A2 A1 A2 A2 A1 9 5 31 32 14 11 44 43 W29 W33 COMMON C NC NO C NC NO J2 K43 COMMON DRAIN COMMON CONTROL BOAR...

Страница 32: ... L3 5 L1 5 TB1 20 TB1 19 10 AWG L1 1 M COMPRESSOR 2 460VAC 3PH 4 HP 6 7 RLA FAN 2 1 05 KW 460VAC 1 8 FLA M FAN 1 1 05 KW 460VAC 1 8 FLA M COMPRESSOR 1 460VAC 3PH 4 HP 6 7 RLA M HEATER 2 70W 460VAC 0 15A HEATER 1 70W 460VAC 0 15A 21 22 K63 22 21 K62 TB1 1 MOUNTED ON T22 F22 F22C F22B F22A 1A 1A 1A 7 10 AMP SET 7A K63 F12 17A 17A K45 17A 17A F13 K43 2 8 4 AMP SET 3 6A 7 10 AMP SET 7A F11 K62 L1 1A F...

Страница 33: ...2 21 COMPRESSOR 2 CONTACTOR TB2 40 TB2 1 TB10 3 TB10 4 TB2 2 TB2 2 TB2 4 TB2 3 TB2 1 OPTIONAL CLSC DRAIN STD DRAIN TB10 2 TB10 1 TB2 2 EVAPORATORTEMP SENSOR REFRIGERANT HI PRES B61 A55 A51 PE IN1 N L PE IN1 OV N L UNLOADING SOLENOID S43 PRES 1 FAN 1 TB2 31 S43 1 TEMP 1 FAN 1 TB2 31 TB2 34 TEMP 1 FAN 2 S45 1 TB2 34 PRES 1 FAN 2 S45 TB2 36 S62 NO COM NO COM OX LOCAL REMOTE START STOP S67 A55 A51 OV ...

Страница 34: ... L3 5A L1 5A L3 5 L1 5 TB1 20 TB1 19 10AWG M COMPRESSOR 2 460VAC 3PH Model2000 4HP 6 7RLA Model2500 6HP 9 1RLA FAN 2 1 05KW 460VAC 3PH 1 8FLA M FAN 1 1 05KW 460VAC 3PH 1 8FLA M COMPRESSOR 1 460VAC 3PH 6HP 9RLA M HEATER 2 70W 460VAC 0 15A HEATER 1 70W 460VAC 0 15A 21 22 K63 22 21 K62 TB1 1 MOUNTED ON T22 F22 F22C F22B F22A 1A 1A 1A 7 10 AMP Model 2000 SET 7A Model 2500 SET 9A K63 F12 17A 17A K45 17...

Страница 35: ... 26 23 22 21 COMPRESSOR 2 CONTACTOR TB2 40 TB2 1 TB10 3 TB10 4 TB2 2 TB2 2 TB2 4 TB2 3 TB2 1 OPTIONAL CLSC DRAIN STD DRAIN TB10 2 TB10 1 TB2 2 EVAPORATORTEMPSENSOR REFRIGERANTHIPRES B61 A55 A51 PE IN1 N L PE IN1 OV N L UNLOADING SOLENOID S43 PRES 1FAN1 TB2 31 S43 1 TEMP 1FAN1 TB2 31 TB2 34 TEMP 1FAN2 S45 1 TB2 34 PRES 1FAN2 S45 TB2 36 S62 NO COM NO COM OX LOCAL REMOTE START STOP S67 A55 A51 OV B62...

Страница 36: ...SOR 2 460VAC 3PH 6 HP 9 1 RLA FAN 1 1 05 KW 460VAC 1 8 FLA M COMPRESSOR 1 460VAC 3PH 6 HP 9 0 RLA M HEATER 2 70W 460VAC 0 15A HEATER 1 70W 460VAC 0 15A TB1 PE FAN 3 1 05 KW 460VAC 1 8 FLA M TB1 PE FAN 2 1 05 KW 460VAC 1 8 FLA M FAN 4 1 05 KW 460VAC 1 8 FLA M 21 22 K63 22 21 K62 TB1 1 ON T22 MOUNTED F22 F22C F22B F22A 1A 1A 1A 7 10 AMP SET 9A K63 F12 17A 17A 17A F13 K43 5 5 8 AMP SET 7 2A 7 10 AMP ...

Страница 37: ...40 TB2 1 TB10 3 TB10 4 TB2 2 TB2 2 TB2 4 TB2 3 TB2 1 OPTIONAL CLSC DRAIN STD DRAIN TB10 2 TB10 1 TB2 2 EVAPORATORTEMP SENSOR REFRIGERANT HI PRES B61 A55 A51 PE IN1 N L PE IN1 OV N L UNLOADING SOLENOID S43 PRES 1 FAN 1 31 1 S43 2 TEMP 1 FAN 3 TB2 31 TB2 34 TEMP 1 FAN 4 S45 2 34 1 PRES 1 FAN 2 S45 TB2 36 S62 NO COM NO COM OX LOCAL REMOTE START STOP S67 A55 A51 OV B62 DISCHARGETEMP SENSOR TB10 3 TB10...

Страница 38: ...50 HPRP1000 1500 575V CUSTOMER CONNECTION 460VTERMINAL CONNECTION X1 L3 PE L2 L1 PE L3 L2 L1 H5 H1 G H5 X1 H1 G RD G Y WH BL WIRING ASSEMBLY DETAIL RD G Y WH BL TRANSFORMER 2 TRANSFORMER 1 575V 460V HES2000 3000 HPRP1750 3000 H6 H7 H3 X2 X3 X4 H2 H4 575V CUSTOMER CONNECTION 460VTERMINAL CONNECTION H6 H3 X2 X3 X4 H2 H4 H7 H8 H8 WIRING ASSEMBLY DETAIL 575V 460V Models 2000 3000 WIRING ASSEMBLY DETAI...

Страница 39: ...MINAL CONNECTION X1 H1 H3 X2 X3 H2 H6 H5 H7 H6 H5 H7 X1 H1 H3 X2 X3 H2 X1 L3 PE L2 L1 PE L3 L2 L1 H5 H1 G H5 X1 H1 G RD G Y WH BL WIRING ASSEMBLY DETAIL RD G Y WH BL TRANSFORMER 2 TRANSFORMER 1 230V 460V HES2500 3000 HPRP1750 3000 230V CUSTOMER CONNECTION 460VTERMINAL CONNECTION H10 H3 X2 X3 X4 H2 H4 H9 H7 H8 H6 H6 H3 X2 X3 X4 H2 H4 H8 H9 H7 H10 WIRING ASSEMBLY DETAIL 230V 460V Models 1500 3000 WI...

Страница 40: ...ers and center support shelf removed for clarity 34 33 2 18 NOTE DRYER SIZES 1500 AND ABOVE USE TANDEM COMPRESSORS 11 2 18 SEE COMPRESSOR DETAIL 28 26 27 29 13 35 RIGHT FRONT VIEW B covers and center support shelf removed for clarity 4 2 32 28 18 LEFT REAR VIEW C covers and center support shelf removed for clarity ...

Страница 41: ...078 3246079 22 Relay High Pressure Cut out1 3246088 3246088 3246088 3246088 3246088 3246088 3246088 3246088 23 Sensor Temperature1 5007289 5007289 5007289 5007289 5007289 5007289 5007289 5007289 26 Switch Fan Cut out 1 3230765 3230765 3230765 3230765 3230765 3230765 3230765 3230765 27 Switch Fan Cut out 2 N A N A N A 3230766 3230766 3230766 3230766 3230766 28 Switch High Pressure Cut out 3230770 3...

Страница 42: ...enter support shelf removed for clarity 32 31 2 16 NOTE DRYER SIZES 1500 AND ABOVE USE TANDEM COMPRESSORS 16 4 10 2 SEE COMPRESSOR DETAIL 34 25 21 11 26 27 RIGHT FRONT VIEW B covers and center support shelf removed for clarity 30 33 4 34 21 25 2 16 11 26 27 LEFT REAR VIEW C covers and center support shelf removed for clarity ...

Страница 43: ...8 4010508 4010508 4010508 4010508 4010508 17 Motor Starter Protector Compressor Digital1 5003506 5003506 5003506 5003506 5003506 5003506 5003506 5003506 18 Motor Starter Protector Compressor Fixed1 5003506 5003506 5003506 5003506 5003506 5003506 5003506 5003506 19 Motor Starter Protector Fan1 3246077 3246077 3246077 3246078 3246078 3246078 3246078 3246079 20 Relay High Pressure Cut out1 3246088 32...

Страница 44: ...0097 5000302 5000302 5000302 5000302 8 Cabinet Panel Front Top Center 5000260 5000260 5000260 5000260 9 Cabinet Panel Rear Bottom 5000112 5000112 5000112 5000112 5000293 5000293 5000293 5000293 10 Cabinet Panel Rear Top 5000125 5000125 5000125 5000125 5000296 5000296 5000296 5000296 11 Cabinet Panel Left Bottom 5001504 5001504 5000100 5000100 5000284 5000284 5000284 5000284 12 Cabinet Panel Left T...

Страница 45: ...43 NOTES ...

Страница 46: ...44 NOTES ...

Страница 47: ...product The foregoing is the exclusive remedy of any buyer of the manufacturer s product The maximum damages liability of the manufacturer is the original purchase price of the product or part THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR STATUTORY AND IS EXPRESSLY IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNE...

Страница 48: ...ww spxflow com hankison Improvements and research are continuous at SPX FLOW Inc Specifications may change without notice ISSUED 12 2017 Form No 5001364 Revision L COPYRIGHT 2017 SPX FLOW Inc HES Series Energy Saving Refrigerated Type Compressed Air Dryers Models HES800 HES1000 HES1250 HES1500 HES1750 HES2000 HES2500 HES3000 ...

Отзывы: