HANK Electronics HKZW-MS02 Скачать руководство пользователя страница 8

against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:

-- Reorient or relocate the receiving antenna.

-- Increase the separation between the equipment and receiver.

-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.

-- Consult the dealer or an experienced radio/TV technician for help.

RF warning statement:
The device has been evaluated to meet general RF exposure requirement.
The device can be used in portable exposure condition without restriction.

Содержание HKZW-MS02

Страница 1: ...e included and operated in any Z Wave network with other Z Wave certified devices The features list 1 Z Wave Plus certified for wide compatibility 500 serials product 2 Supports security 0 and securit...

Страница 2: ...8 42MHz US 921 42MHz ANZ Range More than 100m outdoors About 30m indoors Dimensions 50mm Working current About 50mA Standby current About 20uA Recommended installation height 2m 4m INSTALLATION 1 Turn...

Страница 3: ...s Should false motion alarms be reported check for any moving objects within the sensor s detection area such as trees blowing in the wind cars passing by windmills False motion alarms may be caused b...

Страница 4: ...our Z Wave controller 3 Set the main controller s adding mode see the controller s manual 4 Click the Z button once or triple click the Z button quickly the LED indicator should blink fast 5 Wait for...

Страница 5: ...Switch Smart Dimmer etc Motion sensor supports two association groupings Motion sensor can max associate 5 nodes in each group Group 1 reports the motion detection and battery level Group 2 is assigne...

Страница 6: ...ete NOTE Use this procedure only in the event that the network primary controller is missing or otherwise inoperable ADVANCED CONFIGURATION Motion sensor offers a wide variety of advanced configuratio...

Страница 7: ...the countdown being restarted Available settings 0 65535 seconds Default setting 30 seconds Parameter size 2 byte Parameter No 32 LEVEL OF LOW BATTERY Define a battery level as the low battery Availab...

Страница 8: ...ion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re...

Отзывы: